![Miller DELTAWELD 650 Owner'S Manual Download Page 26](http://html1.mh-extra.com/html/miller/deltaweld-650/deltaweld-650_owners-manual_1796110026.webp)
OM-272476 Page 20
6-2.
TIG Remote Welding Mode - GTAW Process
!
Weld terminals are energized
through the remote control in TIG
Remote welding mode.
1
Mode Switch
2
Right Display
3
Adjust Control
Setup
For typical system connections refer to
Section 6-1.
Rotate Mode Switch to TIG Remote posi-
tion as shown.
The preset amperage is shown in the Right
Display.
Operation
The Adjust Control is used to set desired
preset amperage.
A remote control is required to turn on the
weld output.
.
If the remote control has an amperage
adjustment, the adjustment will func-
tion as a percentage of the preset am-
perage. The Remote In Use indicator
will be lit.
.
For best results, gently scratch the
tungsten electrode to the work to initi-
ate an arc. To minimize arc flare at the
end of the weld, pull back the electrode
quickly to extinguish the arc.
1
2
3
85
263 561-B