![Miller CST 282 Owner'S Manual Download Page 27](http://html1.mh-extra.com/html/miller/cst-282/cst-282_owners-manual_1796104027.webp)
OM-285986 Page 21
�
Complete Parts List is available at www.MillerWelds.com
6-2.
Interface Operation Description
Power Switch
Use switch to turn unit and indicator light On/Off.
VRD Indicator Light
When the unit is configured for low open circuit voltage, this indicator light will illuminate.
High Temperature
Shutdown Light
When unit is first energized this indicator light illuminates for approximately 1 second to provide visual confirmation
that the light is functioning properly. If unit overheats or is operated at an over duty cycle condition, this light will illu-
minate and output will stop (see Section 4-7).
Output Indicator Light
When unit is first energized this indicator light Illuminates for approximately 1 second to provide visual confirmation
that the light is functioning properly and then illuminates continuously.
Amps Display
This display illuminates and shows amperage for either TIG or stick welding process. Measured amperage just prior
to the end of a welding operation will appear on the display for three seconds after welding operation.
Amperage Adjustment
Buttons
Use these buttons to set the desired amperage setting for either TIG or stick welding process.
TIG Process Select
Press and release this button to activate the TIG welding process. Use the amperage adjustment buttons to set the
amperage to the appropriate welding setting.
Lift-Arc
™
Indicator
Light
This light will illuminate when the TIG process is selected.
Arc Control Select
Press until the desired ARC Control setting indicator light is selected (STIFF or SOFT).
Arc Control Indicator
Light
The indicator light for the active ARC Control setting will illuminate when the ARC Control select button is pressed
while in the STICK mode.
STICK Process Select
Press and release this button to activate the STICK welding process controls and switch between electrode types
(EXX10 or EXX18). Press until the desired electrode type is selected. The electrode indicator light of the desired
electrode type will illuminate when selected. Use the amperage adjustment buttons to set the amperage to the ap-
propriate welding setting.
Electrode Indicator
Light
The indicator light for the active STICK electrode type will be illuminated when in the STICK mode.
Table 6–1. Recommended Process Selections vs Electrode Type
Electrode Type
Suggested Process Setting
EXXX1
EXX10
EXXX2
EXX10
EXXX3
EXX18
EXXX4
EXX18
EXXX5
EXX18
EXXX6
EXX18
EXXX7
EXX18
EXXX9
EXX18
Stainless
EXX18
6-3.
Stick Start Procedure-Scratch Start Technique
1
2
3
With Stick selected, start arc as follows:
1
Electrode
2
Workpiece
3
Arc
Drag electrode across workpiece like striking
a match; lift electrode slightly after touching
work. If arc goes out electrode was lifted to
high. If electrode sticks to workpiece, use a
quick twist to free it.
VRD Model Only:
Normal open-circuit volt-
age is not present before electrode touches
workpiece; only a low sensing voltage is
present between electrode and workpiece.
This allows electrode to touch workpiece
without overheating, sticking, or getting
contaminated.
Summary of Contents for CST 282
Page 6: ......
Page 34: ...OM 285986 Page 28 SECTION 8 ELECTRICAL DIAGRAMS Figure 8 1 Circuit Diagram For CST 282...
Page 35: ...OM 285986 Page 29...
Page 40: ...Notes...