5-8.
Connecting 1-Phase Input Power
Input1 2012−05 Ref. 803 766-C / 803 942-A
1
6
5
4
2
3
7
6
L1
L2
1
=GND/PE Earth Ground
3
1
8
9
10
Installation must meet all National
and Local Codes—have only quali-
fied persons make this installation.
Disconnect and lockout/tagout in-
put power before connecting input
conductors from unit. Follow es-
tablished
procedures
regarding
the installation and removal of
lockout/tagout devices.
Always connect green or green/
yellow
conductor
to
supply
grounding terminal first, and never
to a line terminal.
See rating label on unit and check input volt-
age available at site.
1
Black And White Input Conductor (L1
And L2)
2
Red Input Conductor
3
Green
Or
Green/Yellow
Grounding
Conductor
4
Insulation Sleeving
5
Electrical Tape
Insulate and isolate red conductor as shown.
6
Input Power Cord
7
Disconnect Device (switch shown in the
OFF position)
8
Disconnect Device Grounding Terminal
9
Disconnect Device Line Terminals
Connect green or green/yellow grounding
conductor to disconnect device grounding
terminal first.
Connect input conductors L1 and L2 to dis-
connect device line terminals.
10 Over-Current Protection
Select type and size of over-current protec-
tion using Electrical Service Guide (fused
disconnect switch shown).
Close and secure door on disconnect device.
Follow established lockout/tagout proce-
dures to put unit in service.