OM-4420 Page 20
5-7. Engine Prestart Checks
Check all engine fluids daily.
Engine must be cold and on a level surface.
Unit is shipped with 20W break-in oil. The
automatic shutdown system stops engine if
oil pressure is too low or coolant tempera-
ture is too high.
This unit has a low oil pressure shut-
down switch. However, some condi-
tions may cause engine damage before
the engine shuts down. Check oil level
often and do not use the oil pressure
shutdown system to monitor oil level.
Follow run-in procedure in engine manual.
If unburned fuel and oil collect in exhaust
pipe during run-in, see Section 11.
Fuel
Do not use gasoline. Gasoline will
damage engine.
Add fresh diesel fuel before starting to pre-
vent air from entering the fuel system (see
engine maintenance label for fuel specifica-
tions). Leave filler neck empty to allow room
for expansion.
Engine stops if fuel level is low on units with
low fuel shutdown option. Do not run out of
fuel or air may enter fuel system and cause
starting problems. See engine manual to
bleed air from fuel system.
Engine Oil
After fueling, check oil with unit on level sur-
face. If oil is not up to full mark on dipstick,
add oil (see maintenance label for engine oil
specifications).
Cold Weather Starting
To improve cold weather starting:
Use Starting Aid switch (see Section
6-1).
Keep battery in good condition. Store
battery in warm area.
Use fuel formulated for cold weather
(diesel fuel can gel in cold weather).
Contact local fuel supplier for fuel in-
formation.
Use correct grade oil for cold weather
(see Section 8-2).
Full
803 454
Diesel
Full
Engine Oil