OM-4420 Page 18
5-4. Activating The Dry Charge Battery (If Applicable)
Always wear a face shield,
rubber gloves and protective
clothing when working on a
battery.
Remove battery from unit.
11 Vent Caps
12 Sulfuric Acid Electrolyte
(1.265 Specific Gravity)
13 Well
Fill each cell with electrolyte to
bottom
of well (maximum).
Do not overfill battery cells.
Wait ten minutes and check electro-
lyte level. If necessary, add electro-
lyte to raise to proper level. Reins-
tall vent caps.
14 Battery Charger
Read and follow all instruc-
tions supplied with battery
charger.
Charge battery for 12 minutes at 30
amperes or 30 minutes at 5 am-
peres. Disconnect charging cables
and install battery.
When electrolyte is low, add
only distilled water to cells to
maintain proper level.
1
Tools Needed:
2
4
30 A For 12 Minutes
5 A For 30 Minutes
OR
+
−
3
drybatt1 6/05
−
S-0886
5-5. Connecting The Battery
1/2 in
−
+
Connect Negative (
−
) Cable Last.
Tools Needed:
802 168-E / Ref. 202 705 / 802 313 / S-0756-C
Reinstall cover after connecting battery.