OM-249474 Page 24
7-6. Network Wire Feeder Receptacle Functions
9
Pin*
Pin Information
Ref. 245 741-C
A
B
I
C
H
D
G
E
F
A
Not used.
B
Shield.
C
Volt sense.
D
Can low.
E
Can high.
F
+24 volts DC common.
G
+ 24 volts DC
H
Motor v40 volts DC common
I
Motor v40 volts DC
*The remaining pins are not used.
7-7. Optional E-Stop Receptacle Functions
B
A
Ref. 245 741-C
Socket
Socket Information
A
A short to socket B allows unit to weld.
B
A short to socket A allows unit to weld.
The E-Stop option comes with a 2-pin amphenol receptacle, matching plug, and 30 ft (9 m) of high density molded cord to allow connecting the
welding power source into an E-Stop circuit. An integrator will need to supply a closure for the non E-Stop condition. When the E-Stop input
connection changes it state from closed to open, the welding power source goes into an E-Stop mode where all welding outputs shutdown
immediately. Once the input connection returns to a closed state, the unit will start a reset routine and be ready for operation when it completes
the reset routine.
Summary of Contents for 907439002
Page 18: ...OM 249474 Page 12 Notes...
Page 52: ...OM 249474 Page 46 Notes...
Page 64: ...OM 249474 Page 58 Figure 13 2 Circuit Diagram For Axcess E 300 CE 2 Of 2...
Page 65: ...Circuits OM 249474 Page 59 263 464 C Part 2 Of 2...
Page 66: ...OM 249474 Page 60 Figure 13 3 Circuit Diagram For Axcess E 450 CE 1 Of 2...
Page 67: ...Circuits OM 249474 Page 61 263 483 C Part 1 Of 2...
Page 68: ...OM 249474 Page 62 Figure 13 4 Circuit Diagram For Axcess E 450 CE 2 Of 2...
Page 69: ...Circuits OM 249474 Page 63 263 483 C Part 2 Of 2...
Page 70: ...OM 249474 Page 64 Figure 13 5 Circuit Diagram For Axcess E Module...