OM-222166 Page 39
Press Program
button once to enter the Rolling Inductor Program screen.
The screen should look as shown below.
Mode....: Manual
Power
…
: 0.0 KW
Command.: >0.0 KW
Current: 0 A
Run Time: 00:03:00
Voltage: 0 V
Frequency: 4.5 kHz
Rolling Inductor Program Screen
Plug one end of the thermocouple extension cable into TC5 on the power source and the other end into the back of the Rolling Inductor.
If running two Rolling Inductors on the same power source, connect a second thermocouple extension cable from the second Rolling Inductor to
TC6 on the power source.
.
Workpieces should be the same size and material when using two Rolling Inductors on one power source.
NOTICE − TC5 and TC6 connect to the Rolling Inductor internal thermocouple which monitors internal Rolling Inductor core temperatures. Mea-
sure workpiece temperature with temperature crayons, infared sensors, or contact thermocouples within two inches of the Rolling Inductor.
7-6.
Run Status
Run status allows the operator to check status of a program during in-process heating. Depending on the control mode (Temperature or Manual) and
the temperature based mode (Preheat, Bake-Out, PWHT, or Custom), different style screens appear on the display. Run status is for monitoring pur-
poses only and has no selectable or changeable parameters.
7-6-1.
Temperature Based Control
7-6-1-1. Preheat, Bake-Out And PWHT Run Status Screen
Mode.......: Preheat TC5: 77
Target Temp: −−−− TC6: 77
Countdown..: −−:−−:−− TvlIPM(Off): 0
Status.....: Stopped
Run Status Screen
Mode displays the programming mode (Preheat, Bake-Out, PWHT, or Custom Program). During active operation, Target Temp shows the target
temperature based on the specific program, Countdown shows the time remaining in a soak segment, and Status shows the program segment type
(step, soak, ramp, hold, or stopped). TC5 and TC6 display the temperature of thermocouples 5 and 6. This screen is for monitoring purposes only.
7-6-1-2. Custom Program (Not Applicable With Rolling Inductor)
Mode.......: Custom Program TC5: 77
Target Temp: −−−− TC6: 77
Countdown..: −−:−−:−− Segment: 1
Status.....: Stopped
Run Status Screen
During active operation, Target Temp shows the target temperature based on the active segment, Countdown shows the time remaining in a soak
segment, and Status shows the program segment type (step, soak, ramp, hold, or stopped) of the active segment and the active segment number.
TC5 and TC6 display the temperature of thermocouples 5 and 6. This screen is for monitoring purposes only.