OM-222166 Page 19
803 993-D
5-8.
Remote 14 Receptacle RC14 Information and Connections
1
Plug
2
Threaded Collar
3
Keyway
4
Remote 14 Receptacle RC14
(See Section 5-9)
To connect to receptacle, align key-
way, insert plug and tighten
threaded collar.
NOTICE − Use only Miller ProHeat
accessories with a Miller ProHeat
power source.
A
J
B
K
I
C
L
N
H
D
M
G
E
F
3
4
2
1
1
2
5-9.
Remote 14 Socket Information
Socket
Socket Information
A
B
Remote Contactor
+24 volts DC.
Contact closure to A completes 24 volts DC contactor control circuit.
C
D
E
G
Remote Output Control
Command reference; +10 volts DC.
Control circuit common.
Input command signal (potentiometer wiper or 0 to +10 volts DC).
Travel sense detect.
F, J
Power Source Fault
Absence of internal contact closure between F and J signals power source fault to remote con-
trol device (an external power source must be used).
H
I
L
M
N
K
Remote Metering
Tank 2 IRMS (1 volt/10 amperes).
Actual frequency output signal (1 volt/10 kHz).
Average power output signal (1 volt/10 kW).
Voltage output signal RMS (1 volt/100 volts).
Total current output signal RMS (1 volt/100 amperes).
Chassis common.