OM-222166 Page 20
803 993-C
5-10. Temperature Recorder Receptacle RC9 Information And Connections
1
Plug
2
Threaded Collar
3
Temperature Recorder
Receptacle RC9 (See Section
5-11)
To connect to receptacle, insert
plug and tighten threaded collar.
3
2
1
1
2
5-11. Temperature Recorder Socket Information
Socket No.
Socket Information
1
Thermocouple No. 1 (TC1), 0-10 volt DC signal [0V = −50
°
F (−46
°
C), 10V = 1500
°
F (816
°
C)]
2
Thermocouple No. 2 (TC2), 0-10 volt DC signal [0V = −50
°
F (−46
°
C), 10V = 1500
°
F (816
°
C)]
3
Thermocouple No. 3 (TC3), 0-10 volt DC signal [0V = −50
°
F (−46
°
C), 10V = 1500
°
F (816
°
C)]
4
Thermocouple No. 4 (TC4), 0-10 volt DC signal [0V = −50
°
F (−46
°
C), 10V = 1500
°
F (816
°
C)]
5
Signal Common
6
Thermocouple No. 5 (TC5), 0-10 volt DC signal [0V = −50
°
F (−46
°
C), 10V = 1500
°
F (816
°
C)]
7
Thermocouple No. 6 (TC6), 0-10 volt DC signal [0V = −50
°
F (−46
°
C), 10V = 1500
°
F (816
°
C)]
8
Unused
9
Unused
10
Chassis Ground
11
Unused
12
Unused
13
Unused
14
Unused
* The voltage to temperature calculation is:
(DC Volts Out x 155) − 50 =
°
F
(DC Volts Out x 86.1) − 45.4 =
°
C
The ProHeat display should read
±
6
°
F or
±
3.3
°
C.