5-2. Grounding Generator To Truck Or Trailer Frame
!
Always ground generator
frame to vehicle frame to pre-
vent electric shock and static
electricity hazards.
!
Also see AWS Safety &
Health Fact Sheet No. 29,
Grounding of Portable And
Vehicle Mounted Welding
Generators.
!
Bed liners, shipping skids,
and some running gear insu-
late the welder/generator
from the vehicle frame. Al-
ways connect a ground wire
from the generator equip-
ment grounding terminal to
bare metal on the vehicle
frame as shown.
!
Use GFCI protection when
operating auxiliary equip-
ment. If unit does not have
GFCI receptacles, use GFCI-
protected extension cord.
Do not use GFCI receptacles
to power life support equip-
ment.
1
Equipment Grounding
Terminal (On Front Panel)
2
Grounding Cable (Not
Supplied)
3
Metal Vehicle Frame
Connect cable from equipment
ground terminal to metal vehicle
frame. Use #8 AWG or larger insu-
lated copper wire.
Electrically bond generator
frame to vehicle frame by met-
al-to-metal contact.
rot_grnd1 2012
−
03
−
800 652-D
1
3
2
GND/PE
5-3. Using Lifting Eye
Lift1 2008
−
01 804 712
1
Lifting Eye
2
Nut
3
Carriage Bolt
Raise lifting eye until it snaps in
place. Lower lifting eye when not
needed.
To lock the lifting eye in the upright
position, insert a 3/8-16 x 1-1/2 in
carriage bolt through slot in bracket
and secure with nut (bolt and nut not
supplied).
Tools Needed:
2
1
3
Summary of Contents for 907186
Page 6: ......
Page 20: ...OM 4421 Page 14 ...
Page 63: ... Complete Parts List available at www MillerWelds com OM 4421 Page 57 Notes ...
Page 65: ...OM 4421 Page 59 240 152 B ...
Page 66: ...OM 4421 Page 60 Figure 11 2 Circuit Diagram For CC CV Welder Generator ...
Page 67: ...OM 4421 Page 61 240 153 B ...
Page 77: ...OM 4421 Page 71 Notes ...
Page 78: ...OM 4421 Page 72 Notes ...