OM-227 169 Page 15
4-7. Coolant Hose Connections To Dual Output Cables
804 436-A
1
Power Source/Cooler Assembly
2
Liquid-Cooled Output Cable
.
Cables must be the same length: 10 ft
(3 m), 25 ft (7.6 m), or 50 ft (15.2 m).
3
Coolant Hose
4
Dual Output Cable Coolant Hose
Connect output cables to output #1 and
output #2 on power source.
Coolant hoses between output cables and
cooler must be connected in series for dual
output operation. Connect dual output
coolant hose between output cable #1 and
output cable #2 fittings by pushing coolant
hose fitting onto output cable fitting.
Connect quick-connect fitting on both
coolant hoses from cooler to remaining
output cable fittings.
To remove coolant hoses, grasp grey ring
on coolant hose fitting and pull away from
output cable fitting . Coolant hose fitting will
separate from output cable fitting.
.
Fittings have spring loaded valves
inside that close when fitting is discon-
nected from an output cable fitting to
minimize coolant leaks.
.
Heating cables must be the same
length: 30ft (9.1 m), 50 ft (15.2 m), 80ft
(24.2 m), or 140 ft (42.7 m).
.
Total length of heating and extension
cables must not exceed 360 ft (110 m).
The extension cable is counted twice
the length because it has a supply and
return hose.
2
Dual Liquid
−
Cooled
Output Connection
To
Cooler
1
2
1
2
2
3
3
4
2
3
3
4