![Miller 195406 Owner'S Manual Download Page 18](http://html1.mh-extra.com/html/miller/195406/195406_owners-manual_1795884018.webp)
OM-227 169 Page 14
4-6. Coolant Hose Connections To Single Output Cable
804 435-A
1
Power Source/Cooler Assembly
2
Liquid-Cooled Output Cable
3
Protective Cap
4
Coolant Hose
Connect output cable to output #1 on power
source. Connect protective plug to power
source output #2.
Connect quick-connect fitting on both
coolant hoses from cooler to output cable
fittings by pushing coolant hose fitting onto
output cable fitting.
To remove coolant hoses, grasp grey ring
on coolant hose fitting and pull away from
output cable fitting . Coolant hose fitting will
separate from output cable fitting.
.
Fittings have spring loaded valves
inside that close when fitting is discon-
nected from an output cable fitting to
minimize coolant leaks.