OM-254203 Page 5
SECTION 3
−
SPECIFICATIONS
3-1. Serial Number And Rating Label Location
The serial number and rating information for this product is located on the back panel. Use rating label to determine input power requirements and/or
rated output. For future reference, write serial number in space provided on cover of this manual.
3-2. Specifications*
Model
Coolant Tank
Capacity
Maximum Cooling
Capacity
Input Power
Input Power
Cord with
Plug
Dimensions
Weight
Hydracool 1
8 L
1670 Watts
(5698 BTU/hr)
1.0 L/min
(1.1 qt/min)
Single Phase
115 VAC
50/60 Hz
2.5 Amperes
2 m
Length: 305 mm
Height: 674 mm
Width: 263 mm
20.7 kg
8 L
1670 Watts
(5698 BTU/hr)
1.0 L/min
(1.1 qt/min)
Single Phase
230 VAC
50/60 Hz
1.3 Amperes
2 m**
Length: 305 mm
Height: 674 mm
Width: 263 mm
20.7 kg
Hydracool 2
8 L
1760 Watts
(6005 BTU/hr)
1.0 L/min
(1.1 qt/min)
Single Phase
115 VAC
50/60 Hz
2.5 Amperes
2 m
Length: 585 mm
Height: 286 mm
Width: 324 mm
20.8 kg
8 L
1760 Watts
(6005 BTU/hr)
1.0 L/min
(1.1 qt/min)
Single Phase
230 VAC
50/60 Hz
1.3 Amperes
2 m**
Length: 585 mm
Height: 286 mm
Width: 324 mm
20.8 kg
*IEC Cooling Capacity States That The Water Inlet Temperature Can Not Exceed 40
°
C Above Ambient Temperature At A 1l/ Min Flow Rate.
**Plug Is Customer Supplied.
Recirculating Coolant System For Water-Cooled GTAW Torches And GMAW Guns.
Use With Guns/Torches Rated Up To 600 Amperes.
3-3. Coolant Specifications
Do not use conductive coolant.
Application
Coolant
GTAW Or Where High Frequency Current Is Used
Coolant 050024004
Low Conductivity Coolant 043810*
Distilled Or Deionized Water Okay Above
32
°
F (0
°
C)
GMAW Or Where High Frequency Current Is Not Used
Coolant 050024004
Low Conductivity Coolant 043810*
Aluminum Protecting Coolant 043809*
Distilled Or Deionized Water Okay Above
32
°
F (0
°
C)
Where Coolant Contacts Aluminum Parts
Aluminum Protecting Coolant 043809*
*Coolants 043810 and 043809 protect to -37
°
F (-38
°
C) and resist algae growth.
NOTICE
−
Use of any coolant other than those listed in the table voids the warranty on any parts that come in contact with the coolant (pump, radiator,
etc.).
3-4. Environmental Specifications
A. IP Rating
IP Rating
Hydracool 1
−
IP21
This equipment is designed for indoor use and is not intended to be used or stored outside.
IP Rating
Hydracool 2
−
IP23
This equipment is designed for outdoor use. It may be stored, but is not intended to be used outside during precipitation unless sheltered.