background image

OM-293 Page 8

1-4.

Principales normes de sécurité

Safety in Welding and Cutting, norme ANSI Z49.1, de l’American Wel-
ding Society, 550 N.W. Lejeune Rd, Miami FL 33126

Safety and Health Sandards, OSHA 29 CFR 1910, du Superintendent
of Documents, U.S. Government Printing Office, Washington, D.C.
20402.

Recommended Safe Practice for the Preparation for Welding and Cut-
ting of Containers That Have Held Hazardous Substances,
 norme AWS
F4.1, de l’American Welding Society, 550 N.W. Lejeune Rd, Miami FL
33126

National Electrical Code, NFPA Standard 70, de la National Fire Protec-
tion Association, Batterymarch Park, Quincy, MA 02269.

Safe Handling of Compressed Gases in Cylinders, CGA Pamphlet P-1,
de la Compressed Gas Association, 1235 Jefferson Davis Highway,
Suite 501, Arlington, VA 22202.

Règles de sécurité en soudage, coupage et procédés connexes, norme
CSA W117.2, de l’Association canadienne de normalisation, vente de
normes, 178 Rexdale Boulevard, Rexdale (Ontario) Canada M9W 1R3.

Safe Practices For Occupation And Educational Eye And Face Protec-
tion
, norme ANSI Z87.1, de l’American National Standards Institute,
1430 Broadway, New York, NY 10018.

Cutting and Welding Processes, norme NFPA 51B, de la National Fire
Protection Association, Batterymarch Park, Quincy, MA 02269.

1-5.

Information sur les champs électromagnétiques

Données sur le soudage électrique et sur les effets, pour l’organisme,
des champs magnétiques basse fréquence

Le courant de soudage, pendant son passage dans les câbles de sou-
dage, causera des champs électromagnétiques. Il y a eu et il y a encore
un certain souci à propos de tels champs. Cependant, après avoir ex-
aminé plus de 500 études qui ont été faites pendant une période de
recherche de 17 ans, un comité spécial ruban bleu du National Re-
search Council a conclu: “L’accumulation de preuves, suivant le
jugement du comité, n’a pas démontré que l’exposition aux champs
magnétiques et champs électriques à haute fréquence représente un
risque à la santé humaine”. Toutefois, des études sont toujours en cours
et les preuves continuent à être examinées. En attendant que les con-
clusions finales de la recherche soient établies, il vous serait
souhaitable de réduire votre exposition aux champs électromagnéti-
ques pendant le soudage ou le coupage.

Afin de réduire les champs électromagnétiques dans l’environnement
de travail, respecter les consignes suivantes :

1

Garder les câbles ensembles en les torsadant ou en les
attachant avec du ruban adhésif.

2

Mettre tous les câbles du côté opposé de l’opérateur.

3

Ne pas courber pas et ne pas entourer pas les câbles autour de
votre corps.

4

Garder le poste de soudage et les câbles le plus loin possible de
vous.

5

Relier la pince de masse le plus près possible de la zone de
soudure.

Consignes relatives aux stimulateurs cardiaques :

Les personnes qui portent un stimulateur cardiaque doivent avant tout
consulter leur docteur. Si vous êtes déclaré apte par votre docteur, il est
alors recommandé de respecter les consignes ci–dessus.

Summary of Contents for Regency 250

Page 1: ...Regency 250 Processes Description R MIG GMAW Welding Arc Welding Power Source OM 293 120 243N October 2001 Visit our website at www MillerWelds com...

Page 2: ...alue established in 1929 This Owner s Manual is designed to help you get the most out of your Miller products Please take time to read the Safety precautions They will help you protect yourself agains...

Page 3: ...rheating 9 2 3 Volt Ampere Curves 10 2 4 Selecting A Location 10 2 5 Dimensions And Weights 11 2 6 Weld Output Receptacles And Selecting Cable Sizes 11 2 7 Remote 14 Receptacle Information 12 2 8 Elec...

Page 4: ......

Page 5: ...that cord plug is connected to a properly grounded receptacle outlet D When making input connections attach proper grounding conduc tor first double check connections D Frequently inspect input power...

Page 6: ...lding wire at contact tip when not in use D Wear oil free protective garments such as leather gloves heavy shirt cuffless trousers high shoes and a cap D Remove any combustibles such as a butane light...

Page 7: ...intained D Keep high frequency source doors and panels tightly shut keep spark gaps at correct setting and use grounding and shielding to minimize the possibility of interference ARC WELDING can cause...

Page 8: ...a human health hazard However studies are still going forth and evidence continues to be examined Until the final conclusions of the research are reached you may wish to minimize your exposure to ele...

Page 9: ...ation est bien raccord la borne de terre du sectionneur ou que la fiche du cordon est raccord e une prise correctement mise la terre D En effectuant les raccordements d entr e fixer d abord le conduct...

Page 10: ...des v tements de protection d pourvus d huile tels que des gants en cuir une chemise en mat riau lourd des pantalons sans re vers des chaussures hautes et un couvre chef D Avant de souder retirer tou...

Page 11: ...rements et dispositifs de protection LE RAYONNEMENT HAUTE FR QUENCE H F risque de provoquer des interf rences D Le rayonnement haute frequence peut provoquer des interf rences avec les quipements de r...

Page 12: ...hamps magn tiques basse fr quence Le courant de soudage pendant son passage dans les c bles de sou dage causera des champs lectromagn tiques Il y a eu et il y a encore un certain souci propos de tels...

Page 13: ...3 0 1 While idling 2 2 Duty Cycle And Overheating Duty Cycle is percentage of 10 min utes that unit can weld at rated load without overheating If unit overheats thermostat s opens output stops and co...

Page 14: ...g Forks Use lifting forks to move unit Extend forks beyond opposite side of unit 2 Rating Label Use rating label to determine input power needs 3 Line Disconnect Device Locate unit near correct input...

Page 15: ...Sizes Total Cable Copper Length In Weld Circuit Not Exceeding 100 ft 30 m Or Less 150 ft 45 m 200 ft 60 m 250 ft 70 m 300 ft 90 m 350 ft 105 m 400 ft 120 m Weld Output Terminals Welding Amperes 10 60...

Page 16: ...Chassis common The remaining sockets are not used 2 8 Electrical Service Guide Input Voltage 200 230 460 Input Amperes At Rated Output 46 40 20 Max Recommended Standard Fuse Rating In Amperes 1 Time...

Page 17: ...evice Select type and size of overcurrent protection using Section 2 8 Rat ings must comply with applicable codes Install conductors in conduit or equivalent into a deenergized line disconnect device...

Page 18: ...of 2 volts Y Do not change position of Voltage Range switch or Voltage Adjustment switch while welding Arcing can da mage contacts causing connections to fail 3 Power Switch 4 Pilot Light 5 Circuit Br...

Page 19: ...ion 2 9 Check for proper input connections see Section 2 9 Erratic weld output Use proper size and type weld cable see Section 2 6 Clean and tighten all weld connections see Section 4 1 Check for prop...

Page 20: ...OM 293 Page 16 SECTION 5 ELECTRICAL DIAGRAM 192 974 Figure 5 1 Circuit Diagram For Welding Power Source...

Page 21: ...7 THERMOSTAT NO 1 11 T1 191 540 TRANSFORMER pwr main 200 230 460 1 190 789 CAPACITOR ASSY consisting of 1 12 192 727 BRACKET mtg capacitors 1 13 190 790 STRIP mtg center capacitor 1 14 190 793 STRIP i...

Page 22: ...OM 293 Page 18 Hardware is common and not available unless listed 121 587 G 1 2 3 6 7 8 9 10 11 12 11 13 14 4 5 15 Figure 6 2 Panel Front w Components...

Page 23: ...g Amp 213571 2 134 731 CONNECTOR circ pin push in 14 18ga Amp 213603 1 079 739 CONNECTOR circ clamp str rlf sz 17 20 Amp 206322 2 or 143 922 CONNECTOR circ clamp str rlf sz 17 20 Amp 206070 3 9 039 04...

Page 24: ...L consisting of 1 9 TP2 193 248 THERMOSTAT NO 1 10 TP3 193 247 THERMOSTAT NC 1 11 192 994 RECTIFIER SI 1Ph 300A 600PIV top and bottom units 1 12 192 975 BRACKET mtg rectifier 2 13 FM 081 373 MOTOR 1 1...

Page 25: ......

Page 26: ......

Page 27: ...ting Torches Remote Controls Accessory Kits Replacement Parts No labor Spoolmate 185 Spoolmate 250 Canvas Covers Miller s True Blue Limited Warranty shall not apply to 1 Consumable components such as...

Page 28: ...complete and retain with your personal records Always provide Model Name and Serial Style Number Call 1 800 4 A Miller or see our website at www MillerWelds com to locate a DISTRIBUTOR or SERVICE AGEN...

Reviews: