OM-1319 Page 3

1-3.

Additional Symbols For Installation, Operation, And Maintenance

FIRE OR EXPLOSION hazard.

D

Do not install or place unit on, over, or near
combustible surfaces.

D

Do not install unit near flammables.

D

Do not overload building wiring – be sure power supply system is
properly sized, rated, and protected to handle this unit.

FALLING UNIT can cause injury.

D

Use lifting eye to lift unit only, NOT running
gear, gas cylinders, or any other accessories.

D

Use equipment of adequate capacity to lift and
support unit.

D

If using lift forks to move unit, be sure forks are
long enough to extend beyond opposite side of
unit.

OVERUSE can cause OVERHEATING

D

Allow cooling period; follow rated duty cycle.

D

Reduce current or reduce duty cycle before
starting to weld again.

D

Do not block or filter airflow to unit.

STATIC (ESD) can damage PC  boards.

D

Put on grounded wrist strap BEFORE handling
boards or parts.

D

Use proper static-proof bags and boxes to
store, move, or ship PC boards.

MOVING PARTS can cause injury.

D

Keep away from moving parts.

D

Keep away from pinch points such as drive
rolls.

WELDING WIRE can cause injury.

D

Do not press gun trigger until instructed to do
so.

D

Do not point gun toward any part of the body,
other people, or any metal when threading
welding wire.

MOVING PARTS can cause injury.

D

Keep away from moving parts such as fans.

D

Keep all doors, panels, covers, and guards
closed and securely in place.

H.F. RADIATION can cause interference.

D

High-frequency (H.F.) can interfere with radio
navigation, safety services, computers, and
communications equipment.

D

Have only qualified persons familiar with
electronic equipment perform this installation.

D

The user is responsible for having a qualified electrician prompt-
ly correct any interference problem resulting from the installa-
tion.

D

If notified by the FCC about interference, stop using the
equipment at once.

D

Have the installation regularly checked and maintained.

D

Keep high-frequency source doors and panels tightly shut, keep
spark gaps at correct setting, and use grounding and shielding to
minimize the possibility of interference.

ARC WELDING can cause interference.

D

Electromagnetic energy can interfere with
sensitive electronic equipment such as
computers and computer-driven equipment
such as robots.

D

Be sure all equipment in the welding area is
electromagnetically compatible.

D

To reduce possible interference, keep weld cables as short as
possible, close together, and down low, such as on the floor.

D

Locate welding operation 100 meters from any sensitive elec-
tronic equipment.

D

Be sure this welding machine is installed and grounded
according to this manual.

D

If interference still occurs, the user must take extra measures
such as moving the welding machine, using shielded cables,
using line filters, or shielding the work area.

1-4.

Principal Safety Standards

Safety in Welding and Cutting, ANSI Standard Z49.1, from American
Welding Society, 550 N.W. LeJeune Rd, Miami FL 33126
Safety and Health Standards, OSHA 29 CFR 1910, from Superinten-
dent of Documents, U.S. Government Printing Office, Washington, D.C.
20402.
Recommended Safe Practices for the Preparation for Welding and Cut-
ting of Containers That Have Held Hazardous Substances
, American
Welding Society Standard AWS F4.1, from American Welding Society,
550 N.W. LeJeune Rd, Miami, FL 33126
National Electrical Code, NFPA Standard 70, from National Fire Protec-
tion Association, Batterymarch Park, Quincy, MA 02269.

Safe Handling of Compressed Gases in Cylinders, CGA Pamphlet P-1,
from Compressed Gas Association, 1235 Jefferson Davis Highway,
Suite 501, Arlington, VA 22202.
Code for Safety in Welding and Cutting, CSA Standard W117.2, from
Canadian Standards Association, Standards Sales, 178 Rexdale
Boulevard, Rexdale, Ontario, Canada M9W 1R3.
Safe Practices For Occupation And Educational Eye And Face
Protection
, ANSI Standard Z87.1, from American National Standards
Institute, 1430 Broadway, New York, NY 10018.
Cutting And Welding Processes, NFPA Standard 51B, from National
Fire Protection Association, Batterymarch Park, Quincy, MA 02269.

Summary of Contents for Millermatic 250X

Page 1: ...Processes Description MIG GMAW Welding Flux Cored FCAW Welding Arc Welding Power Source and Wire Feeder OM 1319 188 913M October 2000 Millermatic 250X R Visit our website at www MillerWelds com...

Page 2: ...alue established in 1929 This Owner s Manual is designed to help you get the most out of your Miller products Please take time to read the Safety precautions They will help you protect yourself agains...

Page 3: ...0 2 5 Installing Welding Gun 11 2 6 Connecting A Spoolmatic 30A Gun 11 2 7 Setting Gun Polarity For Wire Type 11 2 8 Installing Gas Supply 12 2 9 Installing Wire Spool and Adjusting Hub Tension 12 2 1...

Page 4: ......

Page 5: ...that cord plug is connected to a properly grounded receptacle outlet D When making input connections attach proper grounding conduc tor first double check connections D Frequently inspect input power...

Page 6: ...lding wire at contact tip when not in use D Wear oil free protective garments such as leather gloves heavy shirt cuffless trousers high shoes and a cap D Remove any combustibles such as a butane light...

Page 7: ...aintained D Keep high frequency source doors and panels tightly shut keep spark gaps at correct setting and use grounding and shielding to minimize the possibility of interference ARC WELDING can caus...

Page 8: ...s a human health hazard However studies are still going forth and evidence continues to be examined Until the final conclusions of the research are reached you may wish to minimize your exposure to el...

Page 9: ...tation est bien raccord la borne de terre du sectionneur ou que la fiche du cordon est raccord e une prise correctement mise la terre D En effectuant les raccordements d entr e fixer d abord le conduc...

Page 10: ...r des v tements de protection d pourvus d huile tels que des gants en cuir une chemise en mat riau lourd des pantalons sans re vers des chaussures hautes et un couvre chef D Avant de souder retirer to...

Page 11: ...vrements et dispositifs de protection LE RAYONNEMENT HAUTE FR QUENCE H F risque de provoquer des interf rences D Le rayonnement haute frequence peut provoquer des interf rences avec les quipements de...

Page 12: ...champs magn tiques basse fr quence Le courant de soudage pendant son passage dans les c bles de sou dage causera des champs lectromagn tiques Il y a eu et il y a encore un certain souci propos de tels...

Page 13: ...min W 19 in 483 mm D 30 1 4 in 768 mm 95 kg While idling Operating Temperature Range 20C to 40C Storage Temperature Range 30C to 50C 2 2 Welding Power Source Duty Cycle And Overheating 4 Minutes Weld...

Page 14: ...g power source Curves of other settings fall be tween the curves shown 1 2 4 Installing Work Clamp 1 Work Cable 2 Boot Slide boot onto work cable Route cable out front panel opening from inside 3 Nega...

Page 15: ...Spoolmatic R 30A Gun The Spoomatic 30A welding gun connects directly to the 10 pin receptacle on the front of the welding power source no adapter required NOTE Two welding guns may be connected to th...

Page 16: ...Power Source Gas Hose Connection Connect customer supplied gas hose between regulator flowmeter gas hose connection and fitting on rear of welding power source 7 Flow Adjust Typical flow rate is 20 cf...

Page 17: ...cuit Breaker Rating In Amperes Circuit Breaker 1 Time Delay 2 60 50 30 25 20 Normal Operating 3 80 70 35 30 25 Min Input Conductor Size In AWG Kcmil 8 10 12 14 14 Max Recommended Input Conductor Lengt...

Page 18: ...Connect directly to line disconnect device if hard wiring is required 5 Line Disconnect Device See Section 2 11 Y Special installation may be required where gasoline or volatile liquids are present se...

Page 19: ...and hold wire cut off end Push wire thru guides into gun continue to hold wire Close and tighten pressure assembly and let go of wire Remove gun nozzle and contact tip Turn On Press gun trigger until...

Page 20: ...trol Turn control clockwise to increase voltage Scale around control is ac tual voltage 2 Wire Speed Control Turn control clockwise to increase wire feed speed Scale around con trol is actual wire fee...

Page 21: ...OM 1319 Page 17 3 2 Weld Parameter Table...

Page 22: ...l and carrier Apply light coat of oil or grease to drive motor shaft 4 2 Circuit Breaker CB1 1 Circuit Breaker CB1 If CB1 opens wire feeding stops 2 Welding Gun Check gun liner for blockage or kinks 3...

Page 23: ...oll Securing Nut Turn nut one click to secure drive roll Tools Needed 5 64 in 7 16 in ST 150 227 D 1 3 2 4 5 4 5 Aligning Drive Rolls and Wire Guide Y Turn Off power View is from top of drive rolls lo...

Page 24: ...t voltage or check for low line voltage see Section 2 12 Check input voltage jumper links and correct position if necessary see Section 2 10 Have Factory Authorized Service Agent check main control bo...

Page 25: ...OM 1319 Page 21 SECTION 5 ELECTRICAL DIAGRAM 188 901 A Figure 5 1 Circuit Diagram...

Page 26: ...OM 1319 Page 22 SECTION 6 PARTS LIST Ref 802 059 Hardware is common and not available unless listed Fig 6 2 1 Fig 6 5 3 4 5 6 7 8 9 10 11 12 14 15 Fig 6 3 2 13 17 18 19 Figure 6 1 Main Assembly...

Page 27: ...AMP spring thyristor rectifier 1 173 784 Heat Sink rectifier 2 C3 4 031 689 CAPACITOR rectifier 2 143 818 THYRISTOR SCR 325A 300V hockey puck 2 TP1 154 243 THERMOSTAT NC 1 171 405 Heat Sink rectifier...

Page 28: ...OM 1319 Page 24 ST 802 060 A Hardware is common and not available unless listed 1 2 3 4 5 6 7 8 9 10 12 13 14 11 15 16 17 18 19 20 21 22 23 24 25 26 Fig 6 4 27 28 Figure 6 2 Baffle Center w Components...

Page 29: ...16 PC1 194 103 CIRCUIT CARD control 1 PLG4 131 056 HOUSING RECEPTACLE SOCKETS 1 PLG6 115 092 HOUSING PLUG SOCKETS 1 17 R5 119 998 RESISTOR WW fxd 300W 5 ohm 1 18 TE1 188 910 TERMINAL ASSEMBLY pri 1ph...

Page 30: ...CKETS 1 7 RC7 190 363 RECEPTACLE w SOCKETS 1 8 186 470 PANEL logo 1 9 038 502 Cable Tie 1 10 186 472 PANEL louver Order Item 9 Cable Tie when ordering louver panel 1 11 PL1 157 958 LIGHT ind white len...

Page 31: ...5 ID x 740 OD 2 193 635 RING rtng ext 394 shaft x 1 15 079 633 FITTING hose brs barbed M 3 16tbg 1 16 601 966 SCREW 375 16 x 1 25hexhd 2 18 604 538 WASHER flat stl SAE 312 1 19 124 778 KNOB plstc T 1...