A complete Parts List is available at www.MillerWelds.com
OM-232 386 Page 22
4-15. Connecting An Optional Spool Gun
3
2
1
4
804 922-A
1
Barbed Fitting
.
If spool gun gas hose is
equipped with a pre-installed
barbed fitting, cut off fitting from
end of hose.
Connect spool gun gas hose to
barbed fitting.
2
Gun Trigger Plug
Insert plug into receptacle with
spool gun symbol, and tighten
threaded collar.
3
Negative (−) Output Terminal
4
Positive (+) Output Terminal
Connect weld cable from spool gun
to positive output terminal.