OM-259 Page 18
2-14. Placing Jumper Links
Ref. ST-801 382
Check input voltage available at site.
1
Jumper Link Label
Check label
−
only one is on unit.
2
Jumper Link
Move jumper links to match input volt-
age, and label on unit.
.
Tighten jumper link nuts to 25 in lb
+/- 5 in lb.
2
1
200 VOLTS
230 VOLTS
460 VOLTS
S-072 135-B
L1
L2
L3
L1
L2
L3
L1
L2
L3
3/8, 1/2 in
220 VOLTS
S-177 581
L1 L2 L3
400 VOLTS
L1 L2 L3
440 VOLTS
L1 L2 L3
380 VOLTS
S-177 582
L1 L2 L3
520 VOLTS
L1 L2 L3
S-183 223
THIS MACHINE DOES NOT REQUIRE
SUPPLIED JUMPER LINKS.
575 VOLTS