OM-4409 Page 15
4-5. Stick And MIG Volt-Ampere Curves
208 135 / 203 415 / 208 956
The volt-ampere curve shows the
minimum and maximum voltage
and amperage output capabilities of
the welding generator. Curves of all
other settings fall between the
curves shown.
C. MIG Mode
A. DC Stick Mode
B. AC Stick Mode (Optional)
0
20
40
60
80
100
0
100
200
300
400
500
600
700
800
900 1000
DC AMPERES
DC VOL
T
S
Ranges
300
−
Max
185
−
525
125
−
400
85
−
250
55
−
125
0
20
40
60
80
100
0
100
200
300
400
500
600
700
800
900 1000
DC AMPERES
DC VOL
TS
MAX
MIN
0
20
40
60
80
100
0
100
200
300
400
500
600
700
AC AMPERES
AC VOL
TS
Summary of Contents for Big Blue Air Pak
Page 25: ...OM 4409 Page 21 4 13 Manufacturing Rating Label...
Page 47: ...OM 4409 Page 43 SECTION 9 ENGINE GENERATOR MAINTENANCE 9 1 Engine Maintenance Label...
Page 66: ...OM 4409 Page 62 SECTION 13 CIRCUIT DIAGRAM Figure 13 1 Circuit Diagram For Welding Generator...
Page 67: ...OM 4409 Page 63 221 915 C...