OM-495 Page 32
Return To Table Of Contents
5-12. Connecting To Remote Amperage Adjust Receptacle RC13 On CC Models
Ref. 154 862-A / 048 720-K / 802 311
1
Remote Amperage Adjust
Receptacle RC13
Connect optional remote control to
RC13 (see Section 6-3).
1
5-13. Connecting To Remote 14 Receptacle RC14 On CC/CV Models
Socket*
Socket Information
24 VOLTS AC
A
24 volts ac. Protected by circuit
breaker CB5.
24 VOLTS AC
B
Contact closure to A completes
24 volt ac contactor control
circuit.
C
Output to remote c10
volts dc in MIG or Stick mode;
0 to +10 volts dc in TIG mode.
New! LDR-14 long
distance remote
REMOTE
OUTPUT
D
Remote control circuit common.
distance remote
(includes 120 V
receptacle)
OUTPUT
CONTROL
E
DC input command signal: 0 to
+10 volts from min. to max. of
remote control with Voltage/
Amperage Adjust control at
max.
OR
115 VOLTS AC
I
115 volts, 10 amperes, 60 Hz
ac. Protected by circuit breaker
CB6.
J
Contact closure to I completes
115 volt ac contactor control
circuit.
802 311
GND
K
Chassis common.
NEUTRAL
G
Circuit common for 24 and 115
volt ac circuit.
*The remaining sockets are not used.
Summary of Contents for Big Blue 402D
Page 39: ...OM 495 Page 33 Return To Table Of Contents Notes...
Page 43: ...OM 495 Page 37 Return To Table Of Contents Notes...
Page 54: ...OM 495 Page 48 Return To Table Of Contents 9 2 Maintenance Label...
Page 62: ...OM 495 Page 56 Return To Table Of Contents 10 2 Maintenance Label...
Page 75: ...OM 495 Page 69 Return To Table Of Contents 215 302 A...
Page 77: ...OM 495 Page 71 Return To Table Of Contents 216 530 A...
Page 79: ...OM 495 Page 73 Return To Table Of Contents 215 303 A...
Page 81: ...OM 495 Page 75 Return To Table Of Contents 216 531 A...
Page 83: ...OM 495 Page 77 Return To Table Of Contents 215 298 A...
Page 85: ...OM 495 Page 79 Return To Table Of Contents 215 299 A...
Page 114: ......