OM-203 034 Page 27
6-3. Removing Case and Measuring Input Capacitor Voltage
Turn Off welding power source, and
disconnect input power.
1
Outside Handle Screws
To loosen top, remove two outside
handle screws from both handles
and all side bolts.
2
Interconnecting Board PC2
3
Voltmeter
Measure the dc voltage across the
screw terminals on RC3 and RC5
as shown until voltage drops to near
0 (zero) volts.
Proceed with job inside unit. Rein-
stall cover when finished.
Tools Needed:
5/16 in
802 260 / 801 536
2
3
+ lead to lower right
terminal,
−
lead to
upper right terminal
1
1
!
Significant DC voltage can remain on capac-
itors after unit is Off. Always check the volt-
age as shown to be sure the input capacitors
have discharged before working on unit.
Summary of Contents for 456 CC
Page 4: ......
Page 14: ...OM 203 034 Page 10...
Page 35: ...OM 203 034 Page 31 239 524 A...
Page 36: ...OM 203 034 Page 32 Figure 7 2 Circuit Diagram For CC CV Welding Power Source...
Page 37: ...OM 203 034 Page 33 239 526 A...