OM-203 034 Page 23
5-5. Meter Functions For CC/CV Models
.
The meters display the actual weld output values for approximately three seconds after the arc is broken.
Mode
Meter Reading At Idle
Panel Control (GTAW)
Actual Volts (OCV)
Preset Amps
V
A
80.0
85
Lift-Arc Trigger
Hold TIG (GTAW)
V
A
Blank
Preset Amps
85
TIG (GTAW)
Blank
Preset Amps
V
A
85
MIG (GMAW)
Preset Volts
Blank
V
A
24.5
Pulsed MIG
(GMAW-P)
Pulse Display
Pulse Display
V
A
PPP
PPP
Voltage-Sensing
Wirefeeder
Flashes OCV And Preset
Blank
V
A
80.0
Remote
Control SMAW
Blank
Preset Amps
V
A
85
Panel Control
SMAW
Actual Volts (OCV)
Preset Amps
V
A
80.0