background image

- 10 of 35 - 

2003, the screen will display “EE”.  Please power on the unit 
and re-set time. 

 

Remark: 

If time set is not finished, Measure, Save, Query functions 
shall not be operated; when the device is switched on again, 
time set is still needed.   
 

 
 
Fastening the Wrist Holder 
 

1. Turn left hand so that palm is facing 
upward. Wrap the Velcro wrist holder 
over the left wrist with the LCD display 
facing you. The wrist holder should be in 
contact with your skin directly with no 
shirt sleeve or other clothing between the 
Wrist Holder and your skin as this may 

Measuring Blood Pressure 

Summary of Contents for SF822B

Page 1: ...lood Pressure Monitor Welcome to use MILLENNIUM Microcomputer Blood Pressure Monitor Series Please read the Manual carefully before use so as to operate the Blood Pressure Monitor correctly Please ret...

Page 2: ...agnosis as well as prompt treatment of hypertension is of great significance Attention Hypertension could cause the narrow of arterial blood vessels or the obstacle in twig blood circulation which sha...

Page 3: ...Blood Pressure Blood pressure is the pressure exerted on the arterial walls when blood flows through the arteries The pressure exerted when the heart contracts and sends out blood is called systolic...

Page 4: ...time will probably generate different measuring results SF822B It uses the Oscillometric method of measurement and automatically pressurizes and measures blood pressure and is capable of displaying mi...

Page 5: ...total 90 memories z Query function to view saved pressure data available helping you constantly monitor your blood pressure z Display time and date year month day hour and minute z Clear function to e...

Page 6: ...5 of 35 Name of Each Part Host Set...

Page 7: ...emove the battery compartment cover as illustrated by sliding the cover in the direction of the arrow 2 Insert the batteries as per the polarity indicated inside the compartment 3 Replace the battery...

Page 8: ...y indicator is displayed on the LCD must be two NEW AAA size batteries of the same brand 3 Please use only alkaline batteries instead of rechargeable ones Please replace batteries in case of the follo...

Page 9: ...for query and save mode Day Month Year is in the left lower corner of the screen such us 18 01 2004 09 28 In QUE mode displayed time is measured time of these measurements 2 Time Set Time can be set a...

Page 10: ...ing set key to confirm the second character of day can be set Day month set can be set cyclically Upon finishing set year and pressing SET key if day month and year set is correct the system will auto...

Page 11: ...ice is switched on again time set is still needed Fastening the Wrist Holder 1 Turn left hand so that palm is facing upward Wrap the Velcro wrist holder over the left wrist with the LCD display facing...

Page 12: ...gure Avoid capitulum ulnae wrist tuberositas ulnae bone wrapped in the wrist cuff 3 Pull up the flap of the Wrist Holder and roll to fasten it as illustrated neither leaving any space between the Wris...

Page 13: ...12 of 35 5 If the left hand wrist cannot be used due to reasons such as injury sprain etc you may use your right hand wrist following the above procedure...

Page 14: ...making the center of the Wrist Holder in the same horizontal level as that of your heart 3 The supporting plastic case should not press against the Wrist Holder and the wrist should be held straight...

Page 15: ...ng circumstances a if you measure immediately after drinking alcohol or smoking having meals or after a strenuous physical workout b if you are stressed out have mood swings or have had inadequate sle...

Page 16: ...meanwhile the air relief symbol will disappear This completes the initialization process and the unit is ready for measurement Indicator will appear and the digit 0 zero will show up on the Display T...

Page 17: ...key will not respond to operation before the completion of measurement 5 Gradually ascending pressure value can be seen on the Display Window and you can feel the Wrist Holder tightening your wrist g...

Page 18: ...decrease automatically A buzzer accompanied by flashing of the symbol on the Display Window indicates the beginning of the measurement of your blood pressure and pulse Please wait patiently for the re...

Page 19: ...displayed about 3 5 seconds and 2 seconds respectively 8 Upon the completion of your measurement after you turn the machine on the system will not pressurize automatically in case MEA still displays...

Page 20: ...19 of 35 Fluctuation Within A Day...

Page 21: ...utes to one hour after waking up before breakfast At room temperature of 15 degrees to 25 degrees Celsius 60 F to 80 F After resting your body for more than 30 minutes After using the lavatory When yo...

Page 22: ...recovery speed Generally your blood pressure value taken in a hospital is higher 20mmHg 30mmHg than that taken at home This is caused by a sudden rise of your blood pressure on account of your nervou...

Page 23: ...AVE function The system will not respond to SAVE function other than in the above situation even if the MODE key is pressed down to select the SAVE function followed by pressing SET key to confirm On...

Page 24: ...et key again The system automatically chooses saving order and can save 30 measurements for each one at most Upon the number of sets saved exceeding 30 the system will erase the oldest values and keep...

Page 25: ...y the second or the third person s measurements by pressing MODE key continuously Press SET key again to confirm A set of saved measurement values numbered 1 will appear on the screen The first screen...

Page 26: ...y When the system is in command waiting status press MODE key to select clear function When the mode indication CLR displays in the LCD CLr no 1 displays and CLr is flashing which indicates to clear t...

Page 27: ...emarks 1 The saved data will still be kept in the system when the machine is turned off and then on or after the batteries are replaced 2 The system will appear 0 in case no data has been stored and Q...

Page 28: ...nother measurement Your wrist finger or body moved or you talked while measuring Keep calm quiet for 5 minutes and measure again Wrist Holder worn over shirt sleeve Unbutton sleeve and wrap unit direc...

Page 29: ...imit 240 Faults Causes Fault Treatment Systolic Blood Pressure Value too High while Diastolic Blood Pressure Value too Low Wrong Wrist Holder Location or Wrist Holder incorrectly fastened or you talke...

Page 30: ...lay when turning the machine on by pressing On Off button Battery used out or wrong installation of the batteries The wrist blood pressure measurements are the different with that of upper arm blood p...

Page 31: ...30 of 35 Maintenance Operation Precautions DO NOT drop or give a strong shock to the unit DO NOT inflate the unit without strapping it on your wrist...

Page 32: ...31 of 35 DO NOT attempt to disassemble the unit DO NOT store in extremely low less than 0 C or high more than 60 C temperature Do not expose to moisture...

Page 33: ...32 of 35 DO NOT bend the Wrist Holder in the direction opposite to its shape Warranty will be void if any of the above occurs...

Page 34: ...urement Range Pressure 0 37 3kPa 0 280mmHg Pulse 40 200 Beats Min Accuracy Pressure 0 4kPa 3mmHg Pulse 5 Pressurization Mode Automatic Pressurization Power Supply Two AAA Size Batteries Gross Weight A...

Page 35: ...Humidity RH airpressure Temperature 0 C 40 C Relative Humidity RH 80 Airpressure 50kPa 106kPa 375mmHg 795mmHg Packing Dimension 100mm 83 3mm 88mm L W H Guarantee MILLENNIUM blood pressure monitor is g...