background image

6

LPE-2

LPE-2 REAR PANEL

(1) PHONO INPUTS  "PHONO / LINE INPUTS L/R"

Conventional 3-pin female XLR input connectors for use with all standard phono cartridges. Can also be
used with certain line-level sources. Standard input load resistance is 47,000 ohms. This resistance (2
places, R11 & R40) can be changed by the user to facilitate different phono cartridge load requirements.
See illustration on page 11. Standard input load capacitance is 270 pF. This capacitor (C17) can be changed
by the user if necessary. See illustration on page 12. XLR pin 2 is positive polarity. XLR pin 3 is negative
polarity. Connector contacts are Neutrik Galvatronic gold plated. It is suggested that XLR cable connectors
used with the LPE-2 employ identical plating.

(2) OUTPUTS  "LINE OUTPUT L/R"

Conventional three pin male XLR connectors providing unbalanced, line level output from the LPE-2. Pin 1
and 3 are audio ground. Pin 2 is positive polarity. This output is capable of driving <600 ohm loads and
long, high capacitance cables and has a maximum output level of +26 dBu. Connector contacts are Neutrik
Galvatronic gold plated. It is suggested that XLR cable connectors used with the LPE-2 employ identical
plating.

(3) FILTERS SELECT  "FILTERS IN / OUT"

Two position toggle switch which allows the corrresponding filter section to be switched entirely out of
circuit. When filters are not in-circuit (OUT position, switch down), filter stage amplification has been
bypassed entirely, providing improved overall sonic performance.

(4) EARTH/AUDIO GROUND JUMPER STRAP

A barrier terminal which ties earth ground to audio ground. If ground "hum" loops are experienced when
using the LPE-2, removing this jumper may help. Using this jumper to lift ground, the integrity of the
chassis/earth safety ground connection is never compromised.

(5) AC VOLTAGE MAINS SELECTION  "100-120" or "200-240"

A power entry module with a removable fuse holder block. This fuse holder block is selectable for 100 -
120 Volt or 200 - 240 Volt worldwide mains powering. The fuse block contains two fuses — one fuse is in
series with the hot power line while the other fuse is in series with the neutral power line. Both fuses 

must

be installed. To change the mains voltage selection, remove IEC power connector and assure that the LPE-2
is not connected to mains power. With a non-conductive tool, gently pry the fuse block away from the
power entry module. Remove the two fuses and replace both with type as shown below. Slide out the
internal PC Board, turn it over, and reinsert the PCB so that the desired AC mains voltage appears in the
viewing window. Double check that the fuses installed correspond to the AC mains voltage range which
appears in the viewing window. Gently push the fuse block back until flush and snug.

FUSES:
For 100-120 VAC mains, use two 5 x 20 mm, 1A, slow blow, 250 V, Littelfuse 218 or equiv.
For 200-240 VAC mains, use two 5 x 20 mm, 500 mA, slow blow, 250 V, Littelfuse 218 or equiv.

(6) POWER ENTRY  "IEC Power Receptacle"

An IEC-type AC line-power receptacle for use with removable cords. Use only the power cord provided
with the LPE-2 unit or equivalent U/L approved type SV, SVT, SJ, or SJT AC power supply cord. 

Do not

defeat the third pin earth ground. 

If ground lifting is desired, remove the Earth/Audio Ground Jumper Strap

(topic #4, above).

Summary of Contents for LPE-2

Page 1: ...1 LPE 2 Dedicated to the lives memory and families of Chris Camacho and Gabe Weiner two young men who shared a passion for great audio and who left us much too soon Gabe 1970 1997 Chris 1959 1999...

Page 2: ...al consists of information that is property of Millennia Media Inc and is intended solely for use by the purchasers of the equipment described in this manual Millennia Media Inc expressly prohibits th...

Page 3: ...ects placed on it Pay particular attention to plugs receptacles and the point where the AC power cord exits the LPE 2 4 GROUNDING For your safety it is extremely important that the grounding pin of th...

Page 4: ...ard 2U 19 equipment rack If the LPE 2 is mounted in a road case or other rack which is prone to strong vibration or shock it is highly recommended that the rear of the LPE 2 be supported or otherwise...

Page 5: ...ord press ing 78 45 33 etc can be compensated perfectly with the LPE 2 including vertical groove processes When the LPE 2 does not offer a precise preset compensation point or loading character istic...

Page 6: ...minal which ties earth ground to audio ground If ground hum loops are experienced when using the LPE 2 removing this jumper may help Using this jumper to lift ground the integrity of the chassis earth...

Page 7: ...7 LPE 2...

Page 8: ...with any normal phono input signal The red high level LED illuminates with an audio signal level of approximately 20 dBu and should only illuminate on the very highest peak levels 5 HIGH RESOLUTION PH...

Page 9: ...9 LPE 2...

Page 10: ...C14 on LF board and C8 on HF board The LPE 2 compensation and filter circuits are based upon a unique shunt topology This topology is unlike conventional state variable filters in that only one signal...

Page 11: ...11 LPE 2...

Page 12: ...12 LPE 2...

Page 13: ...e only Ultimately use your ears as the final reference for correct compensation on legacy formats SOURCE SERIES TURNOVER Hz ROLLOFF dB 10 kHz Acoustic Recording such as cylinders etc 0 or as required...

Page 14: ...tsch Grammophone 300 5 Dial 500 or 750 16 Disc 300 16 Ducretet Thomson 450 11 EMI 1931 250 0 33LP 500 12 EMS 375 12 Edison 0 0 Electrola 800 10 Elektra 629 16 Epic thru 1954 COL or 750 16 Esoteric 400...

Page 15: ...ford 750 16 Pacific Jazz 400 12 Parlophone varies with era 300 or 500 0 or 8 5 Pathe inconsistent adjust as required Period 500 16 Polydor 300 8 5 Philharmonia 400 12 Polymusic 500 16 Ploymusic binaur...

Page 16: ...tric early transcriptions 300 0 Westminster pre 1956 500 or 750 16 Westminster AES printed on jacket 400 12 Westrex 200 0 Zonophone early 71 29 RPM 0 0 most 300 0 Per NAB standards the nominal speed o...

Page 17: ...5 dB EIN flat Better than 98 dB EIN RIAA in Three pin XLR Polarity Pin 2 positive polarity Pin 1 ground EQUALIZER SPECIFICATIONS Maximum Filter Boost Cut 10 dB 21 step detent Notch Filter Q Quality Fa...

Page 18: ...l not be liable for special subsequent incidental consequential or punitive damages including but not limited to damage to recordings archives broadcasts mixing consoles or any associated equipment do...