Millar GH604 Instruction Manual Download Page 9

 

 

 

Use cookware the diameter of which is at least as large as the cooking area so that all of the heat produced 

by the heating element is used. 

 

 

 

Make  sure  that  the  bottom  of  tile  pot  is  always  dry  and  clean  to  ensure  good  contact  between  the 

cookware  and  the  cooking  surface.  This  will  also  increase  the  life  of  the  pots  as  well  as  the  ceramic 

glass surface. 

 

Do  not  use  the  same  cookware  that  you  use  for  gas  burners  because  the  concentrated  heat  they 

produce can deform the bottom of the pot. Therefore, you will not achieve best results when using these 

pots on the ceramic glass surface. 

 

 

Notice: 

The glue used to seal the glass surface may leave traces on the appliance. We recommend that 

the module be cleaned with a non-abrasive cleaner before being used for the first time. During the first few 

hours of use, you may detect the smell of rubber. This will disappear after a short time. 

 
 
 
 
 

 

Troubleshooting

 

It  may  occur  that  the  cooktop  does  not  function,  or  does  not  function  properly.  Before  calling  customer 

services for assistance, lets see what can be done. 

 

 

First of all, check to see that there are no interruptions in the gas and electrical supplies, and, in particular, 

that the gas valves for the mains are open. 

 

 

The burner does not light or the flame is not even around the burner.

 

Check to make sure that:

 

 

The gas holes on the burner are not clogged; 

 

All of the movable parts that make up the burner are mounted correctly; 

 

There are no draughts around the cooking surface. 

 
 

The flame does not stay lighted on the model with the safety device.

 

Check to make sure that:

 

 

You press the knob all the way in; 

 

You keep the knob pressed in long enough to activate the safety device. 

 

The gas holes are not clogged in the area corresponding to the safety device. 

 
 

The burner does not remain on when set to "Low".

 

Check to make sure that:

 

Summary of Contents for GH604

Page 1: ...GB Instruction Manual For Built In Gas Hobs Millar Int l Ltd Address 10 Hornby Street Manchester M8 8DQ United Kingdom info millargb com www millargb com...

Page 2: ...ape 7 4 Practical advice 8 5 Troubleshooting 9 6 Health and Safety 10 7 Installation instructions 12 8 Table 1 Burners and nozzle specifications 16 9 Table 2 How to convert gas source 17 10 Table 3 Ad...

Page 3: ...new appliance manufactured with top quality materials will respond perfectly yourrequirements Although you will find this appliance dependable and easy to use we recommend that you read this manual f...

Page 4: ...less they are supervised or taught how to use the appliance by a responsible carer Do not allow children to play with the appliance Before powering the appliance ensure that it is properly adjusted fo...

Page 5: ...5 Close up View GH604 GH705 GH905 GH906 1 Auxiliary Burners 2 Semi rapid burner 3 Rapid burner...

Page 6: ...rried out by a qualified technician in compliance with statutory legislation The specific instructions are given in the section of the handbook reserved for the installer The position of the correspon...

Page 7: ...use rusting and won t remove carbonised stains i e burnt on fat Cleaning enameled parts on a gas hob if present These should be washed with warm water without using abrasive powders or corrosive subst...

Page 8: ...facturer Practical Advice Practical Advise on Using the Burners For best performance follow these general guidelines Use the appropriate cookware for each burner see table in order to prevent the flam...

Page 9: ...se you may detect the smell of rubber This will disappear after a short time Troubleshooting It may occur that the cooktop does not function or does not function properly Before calling customer servi...

Page 10: ...lways use original spare parts This appliance is designed for non professional use in the home and its features and technical characteristics must not be modified These instructions are only valid for...

Page 11: ...about the operation of the appliance Replacement of the electrical outlet because it is disconnect them from the electrical outlet incompatible with the plug Contact service centers authorized by the...

Page 12: ...st be done by means of a hood or electric ventilator that turns on automatically each time the hood is operated In a chimney stack or branched flue Directly to the Outside exclusively for cooking appl...

Page 13: ...cellars ect It is also a good idea to keep only the tank currently being used in the room making sure that it is not near sources of heat ovens fireplaces stoves etc that could raise the internal temp...

Page 14: ...upplied Fig 6 Hook position for Hook position for Hook position for H 30mm top H 40mm top H 20mm top N B Use the hook contained in the accessories set f In the event the cooktop is not installed above...

Page 15: ...form to the standards currently in force The maximum length of the flexible pipes must not exceed 2000 mm Once the connection has been made ensure that the flexible metal tube does not touch any movin...

Page 16: ...hermal power kW Nozzle 1 100 mm Thermal power kW Nozzle 1 100 mm Thermal power kW Nozzle 1 100 mm Thermal power kW Nozzle 1 100 mm Nozzle 1 100 mm Nozzle 1 100 mm Thermal power kW Nozzle 1 100 mm Auxi...

Page 17: ...ust the flame Valve adjustment Valve adjustment should be done with the control knob set at Burner ON saving flame position Remove the knob and adjust the flame with a tiny screwdriver see fig 7 below...

Page 18: ...o 60 per cent savings when proper pots are used Up to 60 per cent savings when the unit is operated correctly and the suitable flame size is chosen It is a prerequisite for efficient and energy saving...

Page 19: ...Natural G25 25 110 265 9 2 4 2064 0 90 774 Natural G25 1 25 118 265 9 2 4 2064 0 90 774 Natural G27 20 120 278 8 2 4 2064 0 90 774 Natural G2 350 13 138 317 6 2 4 2064 0 90 774 Butane G30 30 78 174 2...

Page 20: ...3P G31 37 mbar CH FR GR IE ES GB I2H3 G20 20MBAR G30 G31 28 30 37mbar GR IE IT PT ES GB CH CZ SI SK II2E3B P G20 20mbar g30 30mbar RO II2HS3B P G20 G25 1 25mbar G30 30mbar HU II2ELWLS3B P G20 G27 20mb...

Page 21: ...device It shall be installed and connected in accordance with current installation regulations Particular attention shall be given to the relevant requirement regarding ventilation D CAUTION The use...

Page 22: ...l recycling treatment and environmentally friendly disposal helps reduce possible negative effects on the environment and health and also enables the materials making up the product to be recycled For...

Page 23: ...23...