16
Important:
the wires in the mains lead are coloured in accordance with the following code:
Green & Yellow
- Earth
Blue
- Neutral
Brown
- Live
As the colours of the wires in the mains lead may not correspond with the coloured markings identifying the
terminals in your plug, proceed as follows: Connect the Green & Yellow wire to terminal marked "E"
or
or coloured Green or Green & Yellow.
Connect the Brown wire to the terminal marked "L" or coloured Red.
Connect the Blue wire to the terminal marked "N" or coloured Black.
Adapting the Cooktop for Different Types of Gas
Table1
Burners and Nozzle Specifications
G20/ G25
G25.1
G27
G2.350
G30
G31
Burner
Thermal
power
(kW)
Nozzle
1/100
(mm)
Thermal
power
kW
Nozzle
1/100
(mm)
Thermal
power
kW
Nozzle
1/100
(mm)
Thermal
power
kW
Nozzle
1/100
(mm)
Thermal
power
kW
Nozzle
1/100
(mm)
Nozzle
1/100
(mm)
Nozzle
1/100
(mm)
Thermal
power
(kW)
Nozzle
1/100
(mm)
Auxiliary
(Small) (A)
1.0
71
1.0
75
1.0
79
1.0
98
1.0
52
47
45
1.0
52
Semi rapid
(Medium)
1.80
97
1.80
105
1.80
106
1.80
125
1.8
67
64
59
1.8
67
Rapid (R)
2.40
110
2.40
118
2.40
120
2.40
138
2.40
77
72
67
2.4
77
Triple Ring
(TR)
3.40
125
3.40
142
3.40
143
3.40
185
3.40
93
88
82
3.4
93
Supply
pressures
20mbar
25mbar
20mbar
13mbar
30
mbar
37
mbar
50
mbar
37
Mbar
At 15°C and 1013 mbar-dry gas
P.C.I.G20
37.78 MJ/m
³
P.C.I.G25.1
32.51 MJ/m
³
P.C.I.G25
32.49 MJ/m
³
P.C.I.G27
30.98 MJ/m
³
P.C.I.G2.350 27.20MJ/ m
³
P.C.I.G30
49.47MJ/Kg
Replacement of burner nozzle: loosen the nozzle with a dedicated wrench(7).Fit
the new nozzle, suitable for the required gas type (see table above for
reference)
。