background image

You must follow standard safety guidelines when using electrical products, especially in the presence of children

To avoid electric shock or damage, always make sure that the plug is disconnected before the product is moved or 

cleaned

 

 

Read the instructions carefully.

 

 

 

 

Make sure the product is connected to regular mains (230 V), as indicated on the product label.

 

 

 

 

Be particularly careful if the product is used in the presence of children, the handicapped or elderly.

 

 

 

 

Make sure the cord is situated so that nobody can trip on it.

 

 

 

 

The product must not be used if either the cord or plug is damaged. The product must not be used if it has been 

dropped on the floor or is damaged in any other way which causes it to malfunction.

 

 

 

 

Avoid using extension cords, as such a cord may become overheated and possibly start a fire.

 

 

 

 

If the cord is damaged, it must be repaired by the manufacturer or by an authorized technician to avoid dangerous situations.

 

 

 

 

Never touch the product with wet hands, as this may cause electric shock.

 

 

 

 

The product should not be installed in close proximity to flammable materials of any kind as this will result in the risk of fire.

 

 

 

 

The product must be switched off and the plug must be disconnected before the product is moved.

 

 

 

 

Do not insert your fingers or other objects into the air outlet on the top of the product.

 

 

 

 

Avoid overloading the mains (the circuit) where the product is connected. Pay attention if other electrical apparatus are con-

nected to the same power outlet or circuit.

 

 

 

 

Take into consideration the level of humidity in the room if the room is furnished with wooden furniture or other wood-

work, as continuous dryness may result in the wood splitting.

 

 

 

 

The product cannot be used by children under 8 years of age and persons with reduced physical or mental abilities or who 

lack experience and knowledge of the product, unless they are given supervision or instruction in the safe use of the device 

and understand the hazards involved.

 

 

 

 

Children should not play with the device. Cleaning and maintenance should not be performed by children without supervision.

 

 

 

 

Children under 3 years of age should be kept away from the device, unless under continuous supervision.

 

 

 

 

Children aged 3 to 8 years are only permitted to turn the device ON/OFF, assuming the device is assembled according to the 

assembly instructions and the children have received instruction or supervision in the safe use of the product and understand 

the hazards involved

.

EN

 

 

 

 

 

 

 

 

 

3

 

 

 

 

 

 

         millclimate.com

 

Summary of Contents for TG10B

Page 1: ...uction manual applies to the following models EN 1 millclimate com Read the instructions carefully Use and maintenance must also be in accordance with the instructions Questions related to installation or use of the product should be addressed to the importer ...

Page 2: ...EN 2 millclimate com ...

Page 3: ...ire The product must be switched off and the plug must be disconnected before the product is moved Do not insert your fingers or other objects into the air outlet on the top of the product Avoid overloading the mains the circuit where the product is connected Pay attention if other electrical apparatus are con nected to the same power outlet or circuit Take into consideration the level of humidity...

Page 4: ...ds Normal operation of the unit will not be affect ed but the unit starts working in de icing mode Faulty humidity sensor Flashes every 30 seconds Humidity level should be set to 50 The unit will be in continuous operation mode for fur ther use Please contact Mill International AS if any of the error codes below appear on the display EN 4 millclimate com ...

Page 5: ...EN 5 millclimate com ...

Page 6: ...ded Check to make sure that the space in front of the air intake and air outlet is not blocked On TG20B the hatch for the air outlet automatically goes up while on TG10B this is done manually Make sure that the hatch above the air outlet is in the closed position when switching the product on Applies only to TG20B On TG10B this hatch must be manually opened before starting the device EN 6 millclim...

Page 7: ...to remove the protection in front of the drainage tube outlet Figure 2 Insert the supplied drainage tube diameter 12 mm Figure 3 Make sure that the tube is properly fitted to avoid leakages Insert the supplied drainage tube diameter 14 mm Make sure that the tube is properly fitted to avoid leakages Make sure that the drainage tube is not flat or has other damage as this can reduce the dehumidifyin...

Page 8: ...ow keys simultaneously for 2 seconds Operation indicator When the product receives power standby position the icon will flash When the product is in operation the icon will be continuously lit Water tank indicator When the water tank is full the product will go into standby position and the water tank icon will flash Empty the tank De icing indicator This icon will be lit during de icing of the pr...

Page 9: ...wn into the water tank Disconnect the plug from the outlet when the product is OFF for power conservation and safety UP DOWN arrow keys Use the arrow keys to set the desired humidity level interval 30 80 CO Continuous operation regardless of humidity level Use the DOWN arrow key to get to CO It is one down from 30 humidity When the desired humidity level is 3 off the actual humidity level the prod...

Page 10: ...l panel hold both arrow keys simultaneously for 2 sec onds Operation indicator When the product receives power standby position the icon will flash When the product is in operation the icon will be continuously lit Water tank indicator When the water tank is full the product will go into standby position and the water tank icon will flash Empty the tank De icing indicator This icon will be lit dur...

Page 11: ...set the desired humidity level interval 30 80 CO Continuous operation regardless of humidity level Use the arrow key DOWN to get to CO It is one down from 30 humidity When the desired humidity level is 3 off the actual humidity level the product will stop start the dehumidification process 3 The product will have a fixed position for the hatch above the air outlet when the product is switched on 9...

Page 12: ...er than the detected humidity in the room Set the desired humidity level lower than detected humidity level Drainage tube in continuous op eration is blocked or flat Check the drainage tube and replace it if necessary Make sure that the tube has a sufficient drop Desired humidity lever is not reached after long operation time Open windows or doors Shut windows and doors so that the room is not aff...

Page 13: ...ter once a month if the room is relatively free of dust How to clean the filter A Remove the filter from the back of the product see illustration B Vacuum the filter or wash it with warm water not hotter than 40 C C Let the filter dry D Re insert it in front of the air inlet of the product Check the drainage tube if in use It is important to check that the drainage tube is fitted correctly leakage...

Page 14: ... of together with household waste This product must be deliv ered to a recycling service for electrical appliances and electronic equipment This is done to avoid health risks and prevent harm to the environment Your local utility business or environmental center has an arrangement to ensure the environ mentally correct disposal and recycling of such products When submitting a claim you have to pro...

Reviews: