4CXP Camera
Manufacturer-specific Addresses
page 32 of 70
MIKROTRON GmbH
Manufacturer-specific Addresses
The following registers provide the address in the manufacturer-specific register space of the use-
case feature with the corresponding name.
Image<n>StreamIDAddress
is set to 0 for stream numbers that are not supported by the device.
Remark:
This allows non-GenICam applications, or black-box format converters, to support the
standard use-case and allow continuous acquisition and display of images.
WidthAddress
manufacturer-specific address of Width
HeightAddress
manufacturer-specific address of Height
AcquisitionModeAddress
manufacturer-specific address of AcquisitionMode
AcquistionStartAddress
manufacturer-specific address of AcquistionStart
AcquistionStopAddress
manufacturer-specific address of AcquistionStop
PixelFormatAddress
manufacturer-specific address of PixelFormat
DeviceTapGeometryAddress
manufacturer-specific address of DeviceTapGeometry
Image1StreamIDAddress
manufacturer-specific address of Image1StreamID
ConnectionReset
Writing the value 0x00000001 into this register will reset the Device connection.
Access
read / write
Type:
unsigned integer
In:
0x00000001
Out:
0x00000000
Remark:
A link reset will stop a running image acquisition.
A connection reset command via the master connection (connection 0) will reset a
connection and activate its discovery connection configuration within 200ms. The
camera resets the register to 0x00000000 when it has activated its discovery connection
configuration. Writing by the host should be regarded as “fire and forget” without
waiting for acknowledgment.
In general it is not possible to read this register while it has the value 0x00000001.
DeviceConnectionID
This register provides the ID of the device connection via which this register is read.
Access
read
Type:
unsigned integer
In:
Out:
connection ID
Remark:
A connection ID of zero means that the connection is a master connection. This is a
static register, but with a different value depending from which connection it is read.