background image

Intercell

Intercell 10 B38+B39

The intercell 10 B38+B39 is an outdoor TDD-LTE dual carriers base station with 2*(2*10W) output power (each carrier supports 2x2 MIMO with 10W 

output each RF channel).

Quickstart

Please follow these quick steps to set up your device:

Connect external antennas and Ethernet cable to the connectors (see "

");

Expansion ports and slots

Connect the device to the power source (see "

");

Intercell#Powering

Connect with your laptop to the Ethernet port for configuration.

The device can get the IP address by DHCP and Static assignment;

Once connected, default maintenance IP address: 192.168.200.200, user name: admin, password: MikroTik;

If connecting with Static assignment method, configure the IP address of your laptop as 192.168.200.100/24, then connect through https to the 

device: 192.168.200.200;

Configure backhaul and radio network see "

".

Intercell#Configuration

Powering

The device accepts power in the following way:

Input power jack accepts 48 V DC. The only connector with cable is provided with the package, you will need the power unit - generating 48 V.

The power consumption under maximum load can reach 200 W.

Connect provided cable to your power source.

Connect cable connector to the device.

If using Ethernet cable add RBGESP to the setup, comes with the package.

Configuration

All configuration is necessary to carry out through the webGUI.

The configuration of this device should be done by a qualified person.

Summary of Contents for Intercell 10 B38+B39

Page 1: ...r name admin password MikroTik If connecting with Static assignment method configure the IP address of your laptop as 192 168 200 100 24 then connect through https to the device 192 168 200 200 Config...

Page 2: ...functions of data aggregation and forwarding and S1 X2 proxy Configuration Flow HeNB can get the IP address by DHCP and Static assignment WAN port is SFP port and is named as ID1 in the Network confi...

Page 3: ...t HeNB will reboot to take configuration into effect Connect the HeNB WAN interface back to LAN Login Login WebGUI with https Backhaul parameter Configure NME HeNB GW IP address Path Management Cell S...

Page 4: ...Radio network parameter Configure common radio parameters Path Management Cell Duplex Mode TDD TAC 10 PLMNID 00666...

Page 5: ...ically by HeNB CandidatePCIList 0 503 Note Range from 0 to 503 HeNB will select PCI automatically FreqBandIndicator 39 DL Bandwidth 100 Note 20MHz 100 15 MHz 75 10MHz 50 5MHz 25 UL Bandwidth equal to...

Page 6: ...ally by HeNB CandidatePCIList 0 503 Note Range from 0 to 503 HeNB will select PCI automatically FreqBandIndicator 38 DL Bandwidth 100 Note 20MHz 100 15 MHz 75 10MHz 50 5MHz 25 UL Bandwidth equal to DL...

Page 7: ...rol the RF function select enable RF function when all parameters are well configured Press Submit then HeNB will reboot to take configuration into effect Checking the RF status Path Management Cell C...

Page 8: ...Acceptable pole diameter 50 120 mm Please note the weight of the device is 25kg The package contains mounting accessories 4 x fixed plates 4 x M12 Bolts 4 x M12 nuts Use the M12 bolt and guide throug...

Page 9: ...rame the fixing plate cradle and fix it on the cradle as shown in the picture Keep the 4 fixing screws near the lower side of the chassis fixed on the chassis and leave a 3mm gap for hanging the mount...

Page 10: ...d ports Power supply connector Antenna connectors LED indicating power LED indicating activity GPS antenna connector SNIFF antenna connector Ethernet port connector SFP connector Hardware specificatio...

Page 11: ...radioudstyrstypen Intercell 10 B38 B39 er i overensstemmelse med direktiv 2014 53 EU EU overensstemmelseserkl ringens fulde tekst kan findes p f lgende internetadresse https mikrotik com products DE H...

Page 12: ...zz tal Internet li ej https mikrotik com products NL Hierbij verklaar ik Mikrot kls SIA dat het type radioapparatuur Intercell 10 B38 B39 conform is met Richtlijn 2014 53 EU De volledige tekst van de...

Reviews: