8
After each change of some of these 3 parameters, the device automatically restarts in order
the respective settings to be loaded according to the selected values.
„
rejF“
(0 – 15) – through this parameter the device can be adjusted to decrease its sensibility to
smaller objects without losing its sensitivity to bigger ones. This has its effect only in the mode
with capital letters –
AUTO DISCR.
The greater the value of „
rejF“
, the smaller the sensitivity
to smaller objects. This function can be successfully used for elimination of the surface layer of
soil, i. e., there to not be signals from smaller objects on surface, but to only react to deeper and
bigger objects.
dspB –
(1,2,”Clear cap?“ ) :
-
“
1
”
– capacity of the battery in percent: 0%-100%
-
“
2
”
- working time.
-
“
Clear cap?
”
– clear the capacity of the battery
LCD –
(0 – 7) – light of the display. 0 – turned off, and 1 – 7 – various brightness of light.
If one accidentally pushes
„SELECT“
and it is not necessary any changes to be made on
the settings, the device can be turned again into operation position, through pushing and holding
of
„SELECT“
for 3 sec.
2.2. Setting of the operating parameters in „DISCR“ mode
„STINGER 2“
has 2 basic modes of discrimination -
„NORMAL DISCR“
and
„AUTO
DISCR“,
which are selected through pressing of button
„VCO / DISCR“
as
„AUTO DISCR“
has 8 sub – modes of operation.
„AUTO DISCR“
has the following sub – modes -
„auto discr“
and
„AUTO DISCR“
as
each of them has the function
„accept / ACCEPT“
and
„reject / REJECT“.
Upon activated discrimination, beside the intensity of signal, upon location of metal, on 1
st
and 2
nd
row of the display to the right, both coefficients
ID1
and
ID2
are depicted, which, at
registering of ferrous (magnetic) metal, have negative values, and at nonferrous (non – magnetic)
metal – positive values.
„
ID1“ is a coefficient of purity of metal, and „ID2“ - coefficient of magnetism.
Most often, upon localization of nonferrous metal
ID1
and
ID2
have great positive value,
for e13 and +9. Upon localization of magnetic (ferrous metal) – they have great negative
value, for example -4 and -20.