background image

22

21. To Switch from PSI, KG/CM 2, and BAR

1) With the gauge ON, press and hold down the 

RESET button for at least 6 seconds.

2) The current measuring unit will flash. Press 

the RESET repeatedly to cycle through and 

button to select the desired pressure unit.

3) The setting takes effect 5 seconds after the 

display stops flashing.

22. To Set Pressure Gauge for Automatic 

Shut Off

1) With gauge on, press the (+) or (-) button. 

The previous data will display and the data 

will flash.

2) Press and hold the (+) or (-) button to select 

the desired shutoff pressure. Release the 
button.

NOTICE:

 The number will flash while setting 

the pressure. Hold the (+) or (-) button down 

for about 3 seconds to enter the faster setting 

mode.

3) When the desired pressure setting has been 

selected, and the button has been released, 

the setting will flash for approximately 5 

seconds. When the flashing stops, the 

pressure has been set.

4) The actual inflation pressure  will now be 

displayed

5) Begin inflating. The inflator will shut off when 

the preset pressure is reached or 40 PSI, 
whichever is lower.

NOTICE:

 If the preset pressure is greater 

than (>40 PSI, 2.75 BAR, or 2.80 KG/CM2), 

the inflator will automatically shut off when the 

pressure reaches 40 PSI (2.75 BAR, or 2.80 

KG/CM2). To activate the inflator, release the 
lock-on button and depress it again. 

NOTICE:

 Never set the pressure to more than 

200 PSI.

Air Pressure

Summary of Contents for DI-1015

Page 1: ...DI 1015...

Page 2: ...1 1 1 2 3 4 5 6 7 1 5 7 9 2 4 6 11 8 12 10 13 14 3 8 9 10 11 12 13 14...

Page 3: ...2 2 DI 1015 12 45cm PSI kg cm2 BAR 200PSI 14 kg cm2 13 8BAR 0 9 90 140V 32 104 C 0 40 C...

Page 4: ...3 1 2 3 1 2 3 4 5 1 2 3 4 5 6 7 1 2 3 4 5 6 7 1...

Page 5: ...4 2 3 4 1 1 2 3 4 5 6 m7 7 DC 10B 8 9 1 2 3 4 5 6 7 8 9 1 2 3 4 5...

Page 6: ...5 40PSI 2 75 BAR 2 81KG GM2 6 1 LED 2 80 C 0 C 40 C LED 3 0 40 4 5 NTC 5 40...

Page 7: ...6 1 2 3 4 5 6 10 C 40 C 7 8 25 9 10 6 1 2 7 1 2 8 2 0 0 P S I 13 7BAR 14KG CM 200PSI...

Page 8: ...7 1 2 3 4 5 6 7 9 10 1 2 3 4 5 11 1 2 3 4 12 1 2 3 4 13 1 2 3...

Page 9: ...8 14 LED 15 16 LED LED 17 1 2 3 4 40PSI 2 75BAR 2 80KG CM2 40PSI 40PSI 2 75BAR 40PSI 2 75BAR 2 80KG CM2 18...

Page 10: ...9 19 PSI BAR KG CM2 0 Err 0 20 1 2 3 21 1 RESET 6 2 RESET 3 5 22 1 2 3 3 5 4 5 40PSI 40PSI 2 75BAR 2 80KG CM2 40PSI 2 75BAR 2 80KG CM2 2 200PSI 1 2 m7 m7 3 4 m7 m7 5 6...

Page 11: ...10 1 m7 2 3 1 2...

Page 12: ...pump 1 MAIN PARTS 1 LED Workligh 2 ON OFF Switch 3 Lock On Button 4 Handle 5 Battery Pack 6 Cover 7 Air Hose 8 Air Chuck Clamp 9 Air Chuck 10 Air Chuck clamp storage 11 Tools and Adapters 12 High volu...

Page 13: ...5 Battery Type 12 0 Hose Length 18 in Gauges Digital readout PSI kg cm2 and BAR Maximum Air Pressure Output 200PSI 14 kg cm2 13 8 BAR 2 lbs Battery Type Lithium Ion Charger Input 90 140 V Optimum Char...

Page 14: ...ord suitable for outdoor use reduces the risk of electric shock Personal safety 1 Stay alert watch what you are doing and use common sense when operating a power tool Do not use a power tool while you...

Page 15: ...al objects that can make a connection from one terminal to another Shorting the battery terminals together may cause burns or a fire 4 Under abusive conditions liquid may be ejected from the battery a...

Page 16: ...nce or cleaning to reduce the risk of electric shock 8 Disconnect charger form the power supply when not in use This will reduce the risk of electric shock or damage to the charger if metal items shou...

Page 17: ...self Put the battery pack on a tool and use the tool in a light application After about a minute the battery pack will have warmed itself and will operate normally 4 WHEN TO CHARGE THE BATTERY PACK It...

Page 18: ...pack with groove into the handle to attach the battery pack to the NOTICE When placing the battery pack in battery pack aligns with the groove inside the Improper assembly of the battery pack can caus...

Page 19: ...use serious injury TO LOCK AIR HOSE AIR CHUCK VALVE STEM AIR CHUCK CLAMP TO UNLOCK NOTICE Possible air leaks can cause faulty pressure readings Make sure all connections are tightly secured NOTICE The...

Page 20: ...inflation is complete tighten the locking nut to seal the tire valve Schrader Valve Tool Tapered Adapter Sport Needle Presta Valve Adapter 12 To Use the Presta Valve Adapter 1 Loosen the Presta valve...

Page 21: ...urn off when the lock on button is depressed again The green LED on the FuelGauge indicates that the battery is fully charged The orange LED on the FuelGauge indicates that the battery has used approx...

Page 22: ...flator except those that come with the high volume adapter can be placed in the storage area located on the base 19 DIGITAL GAUGE The digital gauge on the inflator is multifunctional It serves as a pr...

Page 23: ...flash while setting the pressure Hold the or button down for about 3 seconds to enter the faster setting mode 3 When the desired pressure setting has been selected and the button has been released the...

Page 24: ...will result in tool malfunction and electric shock ENVIRONMENT PROTECTION 1 Tool accessories and packaging should be sorted for environment friendly recycling 2 Power tools and accessories at the end...

Page 25: ...Cordless Inflator Pump ltem No DI 1015...

Page 26: ...14 DI 1015P14 Gauge Button 1 15 DI 1015P15 Energy Indicator 1 16 DI 1015P16 Slide Button switch 1 17 DI 1015P17 Push Button Switch 1 18 DI 1015P18 Rubber Handle 1 19 DI 1015P19 Accessory Door 1 20 DI...

Page 27: ...is manufactured and tested according to the following standards EN 60745 1 EN 60745 2 2 EN 62133 EN 55014 1 EN 61000 3 2 EN 61000 3 3 EN 55014 2 and EN 50581 Declared in Taichung Taiwan Dated 2013 01...

Page 28: ...valid m7 warranty card AND invoice receipt copy This warranty card MUST be completed with the following information customer name telephone no dealer name and card date of purchase tool model and ser...

Page 29: ......

Page 30: ......

Page 31: ......

Page 32: ......

Reviews: