1. Determine Charging Options for Battery: Transformer OR Solar

NEVER USE TRANSFORMER AND SOLAR PANEL(S) AT THE SAME TIME!

It will damage the control board!

  

IMPORTANT

 

•  The Mighty Mule 362 is designed and intended for use with a 12 Volt automotive, lawn tractor or marine battery. 

The battery must be placed inside a weatherproof case and located within 6' of the control box. 

The 8' battery 

harness connects the battery to the control board

.

 

•  The battery charge is maintained by the 14 Volt transformer included 

OR 

optional solar panel(s). The transformer 

OR 

solar panel is connected to the control board using low voltage, 16 gauge, dual conductor, multi-stranded, 

direct burial wire [RB509] (page 26)

.

 

•  All low voltage wire used with the Mighty Mule Gate Opener must be 16 gauge dual conductor, multi-stranded, 

direct burial wire

.

 

•  The transformer is intended for indoor use. If the transformer can only be plugged into an outside electrical 

outlet, a weatherproof cover or housing 

must

 be used. 

 

•   If your gate is more than 1000' from an AC power source, you will need to use a solar panel charging kit 

(

minimum 10 watts

) . Refer to the Solar Panels and Gate Activity Chart below.

Solar Panel and Gate Activity Chart

The table and map illustrate the 

maximum number of gate cycles 

to expect per day in a particular 

area when using from 10 to 

20 watts of solar charging power prior to the 

battery depleting to a state where the unit will 

not function. The figures shown are for winter 

(minimum sunlight) and do not account for the 

use of any accessory items.

Accessories connected to your system 

will draw additional power from the 

battery and will require additional solar 

panels.

A deep cycle marine battery is recommended 

for solar and/or high traffic applications. 
NOTE: UP to 250 ft. of dual conductor, 16 

guage, multi-stranded wire may be used 

to allow installation of solar panels in direct 

sunlight.
See page 21:

10 Watt Solar Panel [FM123]

5 Watt Solar Panel [FM121]

Dual Gate 

Winter Ratings

Zone 1

Zone 2

Zone 3

10 Watts

8

16

26

15 Watts

11

20

30

20 Watts

14

28

38

Before You Begin

Summary of Contents for MM362

Page 1: ...on installations vary slightly on different types of gates 120 Volt indoor Transformer surge protector not supplied Horizontal Support Gate Swings Evenly and Freely Hung Firmly and Plumb Post Bracket...

Page 2: ...accessible by or intended to service the general public Vehicular Gate Operator Class Categories WARNING This equipment meets Underwriters Laboratory Standard 325 UL 325 However gate equipment has haz...

Page 3: ...Overview for Pull To Open Gates 6 Installation of the First Gate Opener 7 Install Post Bracket Assembly and Gate Bracket 8 Attach Opener Arm 10 Install the Closed Position Stop Plates 11 Mount the Co...

Page 4: ...l order any accessory not in stock If your store cannot special order accessories please call the Mighty Mule Sales Department 800 543 GATE The Mighty Mule Gate Operator features Dual Sense Technology...

Page 5: ...ted this manual cannot be completely exhaustive in nature They do however provide an overview of the safe design installation and use of this product CAREFULLY READ AND FOLLOW ALL SAFETY PRECAUTIONS W...

Page 6: ...utomatic gate system where a person or object could be caught that increase the risk of injury Entrapment zones must be eliminated guarded or protected 8 When designing a system that will be entered f...

Page 7: ...located at least 10 feet from any moving part of the gate see diagram below Never install any control device where a user will be tempted to reach through the gate to activate the gate operator 5 Do...

Page 8: ...rming any maintenance See page 25 for maintenance procedures 7 To operate this equipment safely YOU must know how to disconnect the operator for manual gate operation see page iii If you have read the...

Page 9: ...blocked or impeded by building structures natural landscaping or similar objects Entrapment Alarm The Mighty Mule Automatic Gate Operator is designed to stop and reverse the gate when the gate comes...

Page 10: ...gates used for vehicles Pedestrians must be supplied with a sepa rate access opening The pedestrian access opening shall be designed to promote pedestrian usage Locate the gate such that persons will...

Page 11: ...ular Swing Gate Operator 362 MMDDYY GTO Access Systems LLC Tallahassee Florida USA 9901178 MM202 SERIES DC Swing Gate Operator P N MM362 Conforms to UL STD 325 Class I Vehicular Gate S N MM362 0000000...

Page 12: ...rging Sleep draw is 15 mA active draw is 2 to 5 A Auto memorization of digital transmitter code GTO RF receiver tuned to 318 MHz Opener length with push pull tube fully retracted is 26 3 8 mounting po...

Page 13: ...de electrical outlet a weatherproof cover or housing must be used If your gate is more than 1000 from an AC power source you will need to use a solar panel charging kit minimum 10 watts Refer to the S...

Page 14: ...place to provide a stable area for mounting the gate bracket is also important Trench the driveway in order to lay PVC conduit for the second opener power cable see illustration on page 6 Your Propert...

Page 15: ...on DVD 1 Gate Bracket 2 Post Pivot Bracket 2 3 8 Bushings 2 Customer Support Card 1 Post Bracket 2 Closed Position Stop Plate 2 2 Mounting Screw 6 E Z GATE OPE NER Transformer 1 RB502 Battery Wire Har...

Page 16: ...ly and the control box page 13 20 If your gate is more than 1000 away from an AC power source you will need to use at least one 10 watt Solar Panel FM123 to charge the 12 Volt battery page 2 26 PVC co...

Page 17: ...the open and closed position at the same time maintaining a stroke distance of 7 to 13 from center of hole in the end of the retracted opener arm to the center of the hole in the gate bracket with th...

Page 18: ...post On wood posts place a metal plate or washer not supplied between the nuts and the post to prevent the thrust of the opener from pulling the bolts and washers out of the wood The post pivot bracke...

Page 19: ...clevis pin and a 3 8 bushing Secure the clevis pin with a hairpin clip Step 4 With the gate in the fully open position and the opener arm fully retracted adjust the post bracket assembly and gate brac...

Page 20: ...bracket assembly to different positions on the post If you are mounting to a post or column larger than 8 or you can not achieve the mentioned clearances you can 1 eliminate the post pivot to try and...

Page 21: ...xcess bolt length with hacksaw or bolt cutters SIDE VIEW TOP VIEW EXAMPLES Post Bracket Mounting Examples Attach Opener Arm Step 1 Attach the opener to the securely bolted post bracket assembly and ga...

Page 22: ...ove the gates to the closed position Step 2 Using appropriate hardware for your type of gate U bolts for tube or chain link screw or bolts for wood or metal attach the closed position stop plate horiz...

Page 23: ...n positions and reattach the gate openers to the gates Control Box 1 KEE P CLE AR Gat e may mov e at any time 2 Do not allo w chil dre n to ope rate gate or play in gate are a 3 This gate is for veh i...

Page 24: ...wire acceptable for use with GTO products is 16 gauge multi stranded low voltage direct burial wire This particular gauge enables the transformer to provide an adequate charge through the control boa...

Page 25: ...he 14VAC OR SOLAR terminals regardless of color polarity Tighten set screws against exposed end of wires A dab of household petroleum jelly on each terminal will help prevent corrosion First Gate Open...

Page 26: ...d BATT Step 2 Run the battery harness wires into the control box through a strain relief slot leaving enough wire to reach the battery wire plugs Step 3 Plug the BLACK battery harness wire into the BL...

Page 27: ...outdoors outlet and transformer should be protected by a weatherproof cover Set the CLOSED Position Limit for PULL TO OPEN Installation Your transmitter must be able to operate the gate If not see Pe...

Page 28: ...l on a radio It controls the amount of force the opener will apply to an obstruction before it automatically reverses direction The Stall Force adjustment is located on the control board Turn the STAL...

Page 29: ...the control box cover is removed the receiver range is reduced to less than 5 feet 0 ECE 1 2 3 4 5 6 7 8 9 ON OFF Switch ON OFF 1 2 3 4 5 6 7 8 9 ECE A23S 12V ALKALINE BATTERY 0 LED WARNING Changes m...

Page 30: ...ole in the gate bracket with the gate in the open position This mounting position will give the opener the most efficient leverage point for operation and provides the least possible pinch area C Afte...

Page 31: ...the JOG OPEN and CLOSE buttons to fine tune the gate position if neccessary C Press and HOLD the SECOND Opener OPEN button on the control board and be prepared to RELEASE the button when the gates rea...

Page 32: ...LAR terminal Insert the other solar panel wire into the remaining 14VAC OR SOLAR terminal The wires can be connected to the 14VAC OR SOLAR terminals regardless of color polarity Step 3 Tighten set scr...

Page 33: ...RST OPR RED 7 8 6 5 4 3 2 AUTOMATIC GATE LOCK ELECTRON IC SECU RITY LOCK 7 8 3 6 Red Blue Black Shield Yellow VAR5 VAR6 K1 PF1 K2 BATT BATT K3 K4 VAR4 VAR3 VAR2 VAR1 MIN MAX OFF JP1 REMOVE JUMPER FOR...

Page 34: ...ut will cycle the operation as follows OPEN STOP CLOSE STOP OPEN 4 EDGE Typically for use with contact edge sensor Activation of this input while gate is moving will cause it to reverse direction for...

Page 35: ...lly shut off after 5 minutes gate will remain disabled until control box is restarted d 1 beep every 20 seconds Low battery is detected e 1 beep every 2 seconds Position sensor on first opener is open...

Page 36: ...__ 13 0 to 16 0 Vac 10 W Solar panel ________________ 18 0 to 22 0 Vdc 600 mA Measure voltage at panel and control box 12 V Battery_____________________ 12 5 to 13 5 Vdc Charging circuit _____________...

Page 37: ...irst use the procedures found in the Visual and Audible Diagnostic Indicators section page 24 2 Use the 24 7 Troubleshooting Wizard at http support gtoinc com 3 If you are unable to solve the problem...

Page 38: ...le Gate Opening Sensor FM138 The Sensor is an electromagnetic sensor which offers hands free operation of the Mighty MuleGate Openor with a 12 ft radius of detection of vehicles in motion A wireless v...

Page 39: ...Mighty Mule entry transmitter to operate your gate operator and your garage door operator Compatible with most garage door operators Driveway Alarm FM231 This device alerts you of vehicles entering y...

Page 40: ...ly visible locations These signs must remain at all times 6 There are no controls installed on the gate operator or within 10 feet of the gate 7 The Dual Sense Technology feature has been properly adj...

Page 41: ...re reserved by GTO and content may not be reproduced downloaded disseminated published or transferred in any form or by any means except with the prior written permission of GTO Any reprinting of GTO...

Reviews: