20
MM362 Installation Instructions
Step 3: Attach Opener Arm (page 10)
Step 4: Install Closed Position Stop Plates (page 11)
Step 5: Mount the Control Box (page 12)
Step 6: Connect Opener Power Cables (page 13)
Step 7: Connect the Transformer (page 13) OR Solar Charger (page 21)
Step 8: Connect Battery Harness (page 15)
Step 9: Connect Battery (page 16)
Step 10: Remove Push-To-Open Jumper
A. Make sure the control box power switch is OFF.
B. Use small pliers to move the JUMPER for PUSH-TO-OPEN
applications.
C. Turn power switch ON. The control board is now configured to
push the gate open. (Keep the jumper, as it is necessary if there
is ever a need to convert the opener for Pull-To-Open).
Step 11: Set the Open Position Limit (Push-to-Open)
Note: Must have a transmitter that operates the gate. If not see Personalize Your Transmitter Setting on page 18.
The CLOSED limit is when the opener is fully retracted and the gate is in the closed position. The closed limit setting can
only be adjusted by moving the gate bracket. To acheive the optimum open position, you must adjust the OPEN Limit
setting:
A. If not already ON slide the ON/OFF switch on the Control Box to the ON position and make sure the arms are in
the CLOSED POSITION (fully retracted).
B. Press and HOLD the FIRST Opener
OPEN button on the control board and
be prepared to RELEASE the button
when the gates reached the desired
open position/limit. Use the JOG
OPEN and CLOSE buttons to "fine
tune" the gate position if neccessary.
C. Press and HOLD the SECOND Opener
OPEN button on the control board and
be prepared to RELEASE the button
when the gates reached the desired
open position/limit. Use the JOG
OPEN and CLOSE buttons to "fine
tune" the gate position if neccessary.
D. NOTE: The opener arms must be extended more than 7 inches to set limits. With the gates in in the desired
open positions PRESS and HOLD the SET LIMIT button until the alarm and RED Light come on. Then release the
button.
E. NOTE: When the control box cover is removed the receiver range is reduced to less than 5 feet. Press the
transmitter button once and allow the gates to fully close. The alarm will beep once when both gates reach the
CLOSED LIMIT. This indicates the LIMITS for both arms are learned and stored in memory.
NOTE: If the gate stops and reverses you may need to adjust the Stall Force (see page 17).
F. Press the transmitter button and allow the gates to fully open to verify that they stop at the desired positions.
Repeat Steps B – E if correction is needed.
Step 12: Adjust Stall Force Setting (page 17)
Step 13: Set Auto Close Time (page 17)
Step 13: Personalize Transmitter Settings (page 18)
MIN
MAX OFF
REMOVE JUMPER FOR
PUSH TO OPEN OPTION
120
SEC.
STALL FORCE
OPEN < JOG > CLOSE
PWR.
SET
LIMIT
1st OPR.
2nd OPR.
STATUS
AUTO CLOSE
FIRST Opener
JOG Buttons
SET LIMIT Button
SET LIMIT Light
SECOND Opener
JOG Buttons
MIN
MAX OFF
REMOVE JUMPER FOR
PUSH TO OPEN OPTION
120
SEC.
STALL FORCE
OPEN < JOG > CLOSE
PWR.
SET
LIMIT
1st OPR.
2nd OPR.
STATUS
AUTO CLOSE
Push-To-Open Jumper