![Mighty Mule 200 E-Z GATE OPENER UL325 SERIES Installation Manual Download Page 32](http://html1.mh-extra.com/html/mighty-mule/200-e-z-gate-opener-ul325-series/200-e-z-gate-opener-ul325-series_installation-manual_1793594032.webp)
28
M i g h t y M u l e 2 0 0
1
CHGR:
Power Input Terminals:
• Input terminals for transformer or solar panel.
• Non-polarity sensitive
2
COM:
• Common/Negative terminal for accessory devices.
3
SAFETY:
(Typically for use with photo beam device,
loop detector or other non-contact sensors)
• Activation of this input while the gate is closing will cause
the gate to stop and return to the opened position.
• Activation of this input while the gate is opening has
no effect. (gate will continue to open)
• Activation of this input while gate is idle will prevent gate
from closing.
• Activation of this input while at open limit will restart the
auto close time (if enabled).
4
EXIT:
(Typically for use with exit loop or wand)
• Activation of this input will open the gate if it’s not already
at the open position.
• Activation of this input while at open limit will restart the
auto close time (if enabled).
5
CYCLE:
(Typically for use with doorbell button or hardwired
keypad)
• Each activation at this input will cycle the operation
as follows:
…. OPEN STOP CLOSE STOP OPEN …
6
EDGE:
(Typically for use with contact edge sensor)
• Activation of this input while gate is moving will cause it to
reverse direction for 2 seconds.
• Activation of this input while idle will prevent gate from running.
7
COM:
• Common/Negative terminal for accessory devices.
8
LOCK +
:
Positive terminal to connect GTO electro-mechanical lock. (FM143)
9
LOCK -
:
Negative terminal to connect GTO electro-mechanical lock. (FM143)
3
6
4
5
7
POWER
LED3
EDGE
COM
LOCK+
LOCK -
PGOK200 Rev.
GTO Inc. Talla
CYCLE
EXIT
SAFETY
COM
CHGR
CHGR
1
2
8
9
NOTE:
• All accessory inputs are dry-contact, normally open, inputs. DO NOT apply external voltage sources
to these inputs.
• All accessory inputs are connected with respect to
COMMON
terminal.
Control Board Connections
LOCK OUTPUTS
CHARGE POWER
INPUTS
ACCES
SORY INPUTS