10
Technical data
Power source
RALLYMIG 161i
Mains voltage ±15% (50Hz-60Hz), V
230
Fuse, A
16
Mains current effective, A
13.0
Mains current max., A
22.9
Power (100%), kVA
2.4
Power max., kVA
4.4
Open circuit power, W
30
Efficiency
0.8
Power faktor
0.99
Current range, A
20-160
Duty cycle, 100% at 20°C, A
135
Duty cycle, 60% at 20°C, A
145
Duty cycle, 40% at 20°C, A
160
Duty cycle, 100% at 40°C, A/V
100/24.0
Duty cycle, 60% at 40°C, A/V
115/24.6
Duty cycle, max. at 40°C, A/%/V
160/25/26.4
Open circuit voltage, V
90
1)
Sphere of application
S/CE
2)
Protection class
IP23S
Norm
EN/IEC60974-1.
EN/IEC60974-5.
EN/IEC60974-10
Dimensions (HxWxL), mm
370x230x450
Weight, kg
13
1)
S
This machine meets the demand made for machines which are to operate in areas with increased hazard of electric chocks
2) Equipment marked IP23S is designed for indoor and outdoor applications
EC DECLARATION OF CONFORMITY
MIGATRONIC A/S
Aggersundvej 33
9690 Fjerritslev
Denmark
hereby declare that our machine as stated below
Type: RALLYMIG 161i
As of week 32, 2013
conforms to directives 2006/95/EC
2004/108/EC
2011/65/EU
European standards: EN/IEC60974-1
EN/IEC60974-5
EN/IEC60974-10 (Class A)
Issued in Fjerritslev on 15 August 2013.
Anders Hjarnø Jørgensen
CEO
0
10
20
30
40
50
60
70
80
90
0
40
80
120
160
I2 [A]
Static Characteristic
RallyMig 161i
MIG Load line
MMA Load line