16
TECHNICAL DATA
We reserve the right to changes
Power source
MIG 305x C/S
MIG 385x C/S
MIG 445x C/S
MIG 545x S
Fuse 230 V
16A
25A
40A
50A
Fuse 400 V
10A
16A
25A
35A
Efficiency
0.85 0.77 0.71 0.74
Cos phi
0.97
0.99
0.99
0.99
Open
circuit
voltage
14-47V 17-43V 18-51V 17-57V
Voltage position
20
24
24
36
100% duty cycle (40°C)
170A
240A
265A
350A
60% duty cycle (40°C)
215A
300A
315A
430A
35% duty cycle (40°C)
285A
335A
405A
505A
Current range min.
40A/16V
40A/16V
40A/16V
40A/16V
Current range max.
300A/29V
385A/28.8V 445A/36.3V 545A/41.3V
Inductance positions
2
2
2
4
1
Protection
class
IP21 IP21 IP21 IP21
2
Sphere of application
S
S
S
S
Standards
EN/IEC60974-1
EN/IEC60974-2
EN/IEC60974-5
EN/IEC60974-10 (Class A)
Dimensions LxWxH C
96x48x85 cm
96x48x85 cm
96x48x85 cm
96x48x85 cm
Dimensions LxWxH S (incl. MWF)
96x48x126 cm
96x48x126 cm
96x48x126 cm
96x48x126 cm
Weight excl. cooling liquid, C
100 kg
135 kg
163 kg
Weight excl. cooling liquid S
121 kg
151 kg
179 kg
220 kg
Cooling unit, tank capacity, C
2.5 L
2.5 L
2.5 L
Cooling unit, tank capacity, S
4.0 L
4.0 L
4.0 L
4.0 L
Cooling C
700 W
700 W
700 W
Cooling S
800 W
800 W
800 W
800 W
Wire feed motor effect C
100 W
100 W
100 W
Wire reel capacity up to C
300 mm
300 mm
300 mm
Wire dimension C
0.6-1.6 mm
0.6-1.6 mm
0.6-1.6 mm
Wire speed C
1.3-18 m/min
1.3-18 m/min
1.3-18 m/min
Mode switch C
2T/4T/ Spot
2T/4T/ Spot
2T/4T/ Spot
Pre-flow C
0.2 secs
0.2 secs
0.2 secs
Soft-start C
0-5 m/min
0-5 m/min
0-5 m/min
Burn-back C
0.05-0.4 secs
0.05-0.4 secs
0.05-0.4 secs
Post-flow C
0-10 secs..
0-10 secs
0-10 secs
C = Compact (internal wire feeding)
S = Separate wire feed unit
1
Indicates that the machine cannot be used outside in the rain
2
S
The machine meets the standards which are demanded of machines working in areas where there is an increased risk of electric
shock