Control panel
15
2
nd
speed pulse time
The time for which the wire runs at 2
nd
speed. If
the welding machine has been set to slow pulse
mode, the value of the parameter cannot be controlled
and will be the same as the one on the welding machine.
Variable 0.2-10 sec.
2
nd
speed value
The 2nd speed value is independent from the pulse
selected on the welding machine.
Variable in the range 0-5 m/min.
USER MENU for special settings and actions
This menu provides a set of commands and
parameters necessary for advanced control of
machine.
Disable the CWF (OFF) and press the
keypad for 3 sec.
The display will show – – –
Rotate the Control Knob to select different
parameters/commands, then activate the selection by
pressing “m/min”.
To change the values of parameters press the knob ON/OFF
and rotate the encoder. Press “m/min” to save the data.
Exit from USER menu
Submenu containing different options
Programs LOCK
If activated, protects programs P3 to P10
against unintentional change of: wire speed,
timings, pulsations.
Panel LOCK
If activated, locks the complete panel with
exclusion of wire inching and keypad ON/OFF.
TRIGGER
Possibility to run/stop the CWF directly by
PI or via an external trigger.
0 = Trigger from PI (default)
1 = Trigger from external signal
2 = Trigger from external
external potentiometer
3 = Trigger from PI + external potentiometer
Unit Alarm
To control the generation of errors on PI in
case of selected CWF is in OFF mode.
0 = no errors are generated (default)
1 = error generated, welding procediment is
stopped and “Fdr” (feeder) will flash on
display of PI.
Device Id
Number used to identify the CWF unit. In case
of more than one unit are connected, different numbers
must be used.
Possible selection is 1..8. Default is 1.
CLEAR
Used to cancel in one step all programs by setting
all parameters to default factory settings.
Factory settings for all programs
(The following settings are set after 3 sec. reset via
from USER MENU)
STATUS
OFF
Wire Inch FORWARD speed
1.0 m/min
PULSE MODE
Disabled
WIRE Speed
1.0 m/min
Start delay
0 sec.
Stop delay
0 sec.
Retract SPEED
0.5 m/min
Retract TIME
0 sec.
Main speed pulse TIME
0.5 m/min
Second speed pulse TIME
0.5 m/min
Second speed
0 m/min