18
Adjustment of wire brake
The wire brake must ensure that the wire reel
brakes sufficiently quickly when welding stops.
The required brake force is depending on the
weight of the wire reel and the maximum wire
feed speed. A brake torque of 1.5-2.0 Nm will be
satisfactory for most applications.
Adjustment:
-
Dismount the control knob by placing a thin
screw driver behind the knob and thereafter
pull it out
-
Adjust the wire brake by fastening or
loosening the self-locking nut on the axle of
the wire hub
- Remount the knob by pressing it back into the
groove.
Selecting welding polarity
Polarity reversal is recommended for certain
types of welding wire, in particular Innershield
welding wire. For recommended polarity, please
refer to the welding wire packaging.
Please note: AUTOMIG
2
183i does not feature
reversed polarity.
Change of polarity:
1. Disconnect the machine from the mains
supply.
2. Dismount screws in the wire chamber with a
wrench (picture 1).
3. Exchange brass plate from plus to minus
(picture 1)
4. Mount screws in the wire chamber with a
wrench (picture 1)
5. Exchange earth cable from minus to plus
(picture 2)
6. Connect the machine to the mains supply.
SOFTWARE
In case of exchange of the control unit, software must be
reloaded, using an SD card.
Latest software can be downloaded under Product software
at www.migatronic.com/login. Save the software on an SD
card containing the folders and one or more of the files
shown below.
To order SD card, use item no. 12646000.
Software reading
Insert the SD-card in the slide in the right side of the
machine.
Turn on the machine.
The display flashes shortly with three lines.
Wait until the set current is displayed.
Turn off the machine and remove the SD card.
The machine is now ready for use.
All machine user settings are deleted when new
software has been inserted. Therefore, always
remove the SD-card from the machine after the
software update. Thereby, continuous software
update is avoid each time the machine is turned on.