The Drive-Alert is adjusted at the factory for maximum sensitivity for the probe and minimum time for the whistle. To adjust these, open the 
control panel and adjust the small pots according to the diagram on the inside cover (see FIGURE 2). The whistle “timer adjust” is 
adjustable from 1-12 seconds and the LED 3 will light.

When first plugged in, the red blanker LED 2 will remain on for only 1 minute, and the Drive-Alert will be muted for approximately 1 
minute each time the electrical power is turned on. It provides time for the electronic circuits to initialize.

During normal operation, the noise blanker detects unwanted electrical interference and mutes the Drive-Alert for a few seconds. It has 
been adjusted at the factory.  The blanker light should be off during normal operation.

To test the Control Panel, it is possible to rub your finger simultaneously on the three terminals to which the sensing probe is attached. This 
should cause the system to go into false alarm. This will occur with or without the sensing probe attached. Be sure the terminal screws are 
tight while making the test. If the system responds to this test, in almost all instances it indicates a properly functioning control panel.

If false alarms occur, remove the sensing probe wires fron the Drive-Alert terminals. Let the power remain turned on to the control panel. 
If the false alarm stops, then the most likely cause of the problem is moisture in the sensing probe cable. Radio transmitters, cell phones, 
cordless phones, and wireless modems within 10 feet of the control panel may cause false alarms. 

Additional devices can be attached to the Drive-Alert on its terminals at the bottom of the control panel. When the whistle switch is turned 
off, the Drive-Alert terminals can switch customer provided electrical current up to 5 AMPS. Never attach any device that puts more than 30 
volts DC on the Drive-Alert terminals. When the whistle switch is turned on, the Drive-Alert terminals have available 24 VDC at 100 MA. 
Refer to the diagrams in this manual for hookup instructions.

Mier Products has a hard-wired “timer control” accessory available.  The DA-505 Timer Control attaches to the Drive-Alert terminals. This 
Timer Control is adjustable from 45 seconds to 45 minutes. It switches up to one thousand watts of 115 volt power for outside lights. Mier 
Products also has a hard-wired chime available.  The DA-655 Chime with Volume Control is the most popular accessory for the DA-500, 
and is highly recommended for drive-up window or business applications.  Mier also has a wireless “timer control” kit (DA-606LK) which 
adjusts from 45 seconds to 45 minutes and includes a DA-071 Light Switch and DA-072 Lamp Module to control lights as an alert in addi-
tion to the audible alert.  Furthermore, Mier has a chime transmitter (DA-066MP) which triggers wireless DA-078 Wireless Plug-in Chimes.  

NOTE: 

When using multiple accessories, add a DA-500LKA which provides additional relay contacts to a DA-500.

Along with Mier’s accessories, the DA-500 can also trigger your other devices such as surveillance, bells, 

sirens, signs, gates, and much more!

FIGURE 2

DA-500 CONTROL PANEL ADJUSTMENTS

BLANKER ADJUST

BLANKER

LED 2

TIMER ADJUST

MAX

MIN

SENSITIVITY

MAX

MIN

LED 3 ALARM

1 AMP FUSE

RELAY

POWER 

LED 1

MAXIMUM CONTACT CURRENT IS 100 MILLIAMP AT 

24 V WHEN USING DRIVE-ALERT VOLTAGE SUPPLY

SENSOR

RELAY

DO NOT CONNECT TO 120V AC

800-473-0213   ~   [email protected]   ~   www.mierproducts.com

Summary of Contents for DA-500

Page 1: ...oor lights and or lamps to warn strangers or welcome friends 7 Attach video surveillance to record activity and display the driveway on a monitor inside 8 Add a repeater to send the signal another 100...

Page 2: ...ncrements Ex DA 051 250 is a sensor with 250 feet A Hard Wired DA 655 Chime with Volume is the most popular accessory for the DA 500 and is HIGHLY recommended for all business drive up window and high...

Page 3: ...rect burial cable are buried 6 to 8 inches deep and parallel to the driveway IT IS HIGHLY RECOMMENDED the sensor and the cable be buried in PVC pipe to protect them over time from rocks migrating up o...

Page 4: ...isture from entering the cable and causing problems such as false alarms See FIGURE 2 The sensing probe is a 1x12 inches cylinder containing a sealed sensor Be cautious when handling the sensor and pa...

Page 5: ...can be attached to the Drive Alert on its terminals at the bottom of the control panel When the whistle switch is turned off the Drive Alert terminals can switch customer provided electrical current...

Page 6: ...DA 100CP 1 2 3 4 5 6 7 8 SENSOR DA 500 Connecting DA 066MP Wireless Chime Transmitter for DA 078s Sensor Wires Red to 1 Black to 2 Silver Shield to 3 DA 066MP DA 078 Black to 4 NEG Ground Red to 5 24...

Page 7: ...Wires Red to 1 Black to 2 Silver Shiield to 3 Red to 5 24 Volt DC Black 16 gauge wire 120V Source 10amps max Black wires to lights Internal Relay Contact 1 2 3 4 5 6 7 8 SENSOR DA 500 Whistle Switch M...

Page 8: ...ever if internal piezo whistle is not wanted move the DA 500 Whistle Switch to the OFF position and connect the jumper between 24 and the C Terminal External 24VDC Whistle Bell or Horn with the DA 500...

Page 9: ...0 Sensor HARD WIRED DRIVE ALERT ACCESSORIES DA 655 DA 500LKA DA 052V DA 505 DA 505W DA 050 The Hard Wired DA 655 Chime with Volume Control is our most popular accessory for the model DA 500 Drive Aler...

Page 10: ...buffering with an external relay in the non dry contact mode but safety care should be taken for the event a person or vehicle in the gate s path Q Can vehicles be counted using the Drive Alert A Yes...

Page 11: ...l block and see if panel is quiet Replace Sensor Cable Remove Shield bare wire from terminal 3 of terminal block and retry Fix Not fixed Not fixed Not fixed Replace Accesso ries Fix Fix Call Mier Prod...

Page 12: ...ring overload of Drive Alert System or Drive Alert accessory output or components attached to the Drive Alert parts Drive Alert models and accessories must be shipped handled stored and installed with...

Reviews: