Connection of machines
supplied with a cable and plug
– 230 - 240 V / 1N / 50 Hz
(13 A fuse rating U.K.)
Connection should be made via a fused
plug and suitable switched socket
which is easily accessible after installa-
tion.
For extra safety it is advisable to install
a residual current device (RCD), with a
trip current of 30 mA (in accordance
with DIN VDE 0664, VDE 0100 Section
739).
Do not connect via an extension lead.
Important
The wires in the mains lead are col-
oured in accordance with the following
code:
Green/yellow
= earth
Blue
= neutral
Brown
= live
Where it is necessary to change plugs,
if the colours of the wires in the mains
lead of this appliance do not corre-
spond with the coloured markings iden-
tifying the terminals of your plug, pro-
ceed as follows:
– The wire which is coloured green
and yellow must be connected to the
terminal in the plug which is marked
with the letter E or by the earth sym-
bol
z
or coloured green, or green
and yellow.
– The wire which is coloured blue must
be connected to the terminal in the
plug which is marked with the letter
N or coloured black.
– The wire which is coloured brown
must be connected to the terminal in
the plug which is marked with the let-
ter L or coloured red.
WARNING:
THIS APPLIANCE
MUST BE EARTHED
Installation
45