Notes for the installer
Coin mechanism unit
The washer-extractor can be fitted with a coin
unit.
It can also be connected to an existing coin
unit. The correct connection cable is required
for this. For the C 4030/31 and C 4050/51
using timed operation an AD 3 adapter is re-
quired.
The machine has to be reprogrammed for this
connection. This must only be done by a
Miele authorized service engineer.
The coin unit and connection cable are avail-
able at extra cost from the Miele Spare Parts
Department, or from Miele specialist dealers.
Electrical connection
All electrical work must be carried out by a
suitably competent person in compliance with
national and local regulations.
Please take note of the Installation diagram
and the Wiring diagram. They are important
for electrical connection.
The electrical safety of this machine (WS
5073, 5100, 5140, 5101, 5141) is in accord-
ance with IEC 335.
The minimum suds level required for activat-
ing the heating is given in mm column of
water: WS 5073
45 mm column of water
The voltage and frequency are given on the
data plate. The machine must only be con-
nected if these match the mains supply.
Variants:
3N AC 380-415 V 50 Hz
1 AC 220-240 V 50 Hz
The motor is fitted with an overload protection
switch.
For extra safety it is advisable to install a re-
sidual current device with a trip current of 100
mA.
Nominal rated load and fuse rating are given
on the data plate. Ensure that these are com-
patible with the electricity supply.
WARNING
THIS APPLIANCE MUST BE EARTHED
Connection should be made via a suitable iso-
lator which complies with national and local
regulations, and the on/off switch should be
easily accessible for servicing work.
When installation and connection have
been completed all removable outer pa-
nels must be re-fitted before the machine
is operated.