Exhaust - venting
The shorter the exhaust ductwork, the
more efficient the dryer will be. Ex-
pelled air is slowed down in the ducts
due to friction against the inner walls.
The shorter and smoother the inner
walls are, the less affected friction will
have.
An elbow or bend creates more friction
than a straight duct. An additional duct
length factor must therefore be added
for each elbow or bend (see Table I).
This factor expresses the resistance of
the bend in terms of a straight length of
duct.
The additional length factor is then
added to the measured duct length to
give the effective duct length.
A larger duct diameter also helps to re-
duce friction. The duct diameter should
therefore be increased with increasing
duct length.
To calculate the effective duct length.
Measure the actual duct length
needed.
Establish the number of elbows or
bends necessary, noting the type of
bend, angle and radius involved
(see Table I).
Add the additional length factor as
specified in Table I to the actual duct
length to give the effective duct
length.
The necessary duct diameter should
then be found in Table II.
Note:
Drying times and energy consumption
remain unaltered for 4’’ duct up to a
total length of 32 3/4’.
Longer duct may lead to slight in-
creases in drying times and energy
consumption but will not impair the
function of the machine as long as the
necessary duct diameter is used (see
Table II).
Tabel I
Type of bend
Angle
Radius in inches
Additional duct
length in ft
Flexible metal pipe
90°
90°
45°
4’’ - 12’’
12’’ - 20’’
4’’ - 20’’
1 3/4‘
1 1/4’
1 1/4’
Smooth metal pipe
90°
4’’
1 1/4’
Elbow
8 1/4’
Concertina bend
90°
8’’
2 3/4’
Segmented bend
90°
8’’
2’
Wall vent kit with louvres, or window
vent kit
Wall vent kit with flap, or window vent kit
12 1/2’
5’
Exhaust connection, right side
Exhaust connection, left side
Flat section adaptor, left side
32 3/4’
19 3/4’
59’
26