1. Remove the cap assembly (Section 5.6).
2. Remove the two Phillips screws securing the motor to the rear casing and
disconnect its electrical connections.
3. The location of individual components is shown in Figure 5-34.
Important:
When re-installing the motor care must be taken to ensure that the rubber
cushion (Figure 5-34, Item 4) and the motor seal (Figure 5-34, Item 7) are
correctly located! The speed control will vary depending on the type of power
selector switch installed.
Figure 5-34:
S 27x Motor Assembly
1
Motor brushes
8
Motor
14
Speed control electronic:
EDL 202, S 271i - S 276i
EDL 302, S 280i -S 282i
EDL 402, S 278i
2
Clamping
bracket
9
Retaining screw
15
Retaining screw
3
Retaining screw
10
Holding bracket
16
Plug
4
Rubber cushion
11
Retaining screw
17
Plug housing
5
Retaining screw
12
Thermostat
18
Retaining screw
6
Holding bracket
13
Resistor
19
Retaining screw
7
Motor seal
20
Interference suppression
capacitor