Technical Information
36
S 2xx, S 3xx & S 4xx Canister Vacuums
5.8 Foot
Switches
5.8.1
S 25x and S 27x
1. Remove suction power selector (S 27x only).
2. Press the locking tab (Figure 5-14, Item 1 or 2) down with a small
screwdriver and slide out the appropriate foot switch.
Figure 5-14:
Foot Switches, S 25x and S 27x
5.8.2 S
3xx
1. Press the foot switch (Figure 5-15, Item 1) down.
2. At the same time, use a small screwdriver to release the catch (Figure 5-
15, Item 2).
3. Remove the foot switch upwards from the cap assembly.
Figure 5-15:
Foot Switch, S 3xx
5.8.3
S 4xx
1. Remove the cap assembly (Section 5.6).
2. Loosen the on/off and cord rewind foot switches. Use a screwdriver to
release the retaining clips at Figure 5-16, Item 3, and push out the foot
switches.