en - Technical data
50
Direct steam heating
Heater rating (peak capacity high pressure)
37 kW
Threaded union (on site)
1 x
½
"
Steam solenoid valve, dirt filter and steam shut-off valve must be installed by the customer on site. Follow the installation instructions
for steam-heated machines.
Drainage
Maximum drain water temperature
95 °C
Waste water connection (on machine)
Plastic pipe HT DN 70
Drain (on site)
Connection DN 70
Maximum drainage rate
200 l/min
Connection for equipotential bonding
Male thread
M10
Toothed washers
M10
Installation dimensions
Casing width (without add-on components)
920 mm
Casing height (without add-on components)
1447 mm
Casing depth (without add-on components)
754 mm
Overall machine width
924 mm
Overall machine height
1450 mm
Overall machine depth
846 mm
Minimum width of transport opening
1020 mm
Minimum safety distance between wall and appliance front
1280 mm
Diameter of door opening
415 mm
Door opening angle
180°
Anchoring
Standard
Required anchor points
2
DIN 571 wood screw (diameter x length)
12 mm x 90 mm
Rawl plugs (diameter x length)
16 mm x 80 mm
With plinth (APWM UO/UG)
Required anchor points
4
DIN 571 wood screw (diameter x length)
12 mm x 90 mm
Rawl plugs (diameter x length)
16 mm x 80 mm
Concrete plinth
Required anchor points
2
DIN 571 wood screw (diameter x length)
12 mm x 90 mm
Rawl plugs (diameter x length)
16 mm x 80 mm
Summary of Contents for PWM 916 SD
Page 2: ...2 de 4 en 29 fr 53 es 77 ru 102 it 128 ...
Page 22: ...de Aufstellung INSTALLATION 22 Standard Maßangaben in Millimeter Standfuß ...
Page 23: ...de Aufstellung INSTALLATION 23 Sockel Maßangaben in Millimeter ...
Page 46: ...en Installation INSTALLATION 46 Standard Dimensions in mm Machine foot ...
Page 47: ...en Installation INSTALLATION 47 Plinth Dimensions in mm ...
Page 70: ...fr Installation INSTALLATION 70 Par défaut Dimensions en millimètres Pied ...
Page 71: ...fr Installation INSTALLATION 71 Socle Dimensions en millimètres ...
Page 95: ...es Emplazamiento INSTALLATION 95 Estándar Medidas en milímetros Base de apoyo ...
Page 96: ...es Emplazamiento INSTALLATION 96 Zócalo Medidas en milímetros ...
Page 121: ...ru Установка INSTALLATION 121 Стандарт Размеры в мм Ножка ...
Page 122: ...ru Установка INSTALLATION 122 Цоколь Размеры в мм ...
Page 146: ...it Posizionamento INSTALLATION 146 Standard Misure in millimetri Piedino ...
Page 147: ...it Posizionamento INSTALLATION 147 Base Misure in millimetri ...