en - Installation notes
*INSTALLATION*
32
Tip:
We recommend connection to the power supply via a suitably
rated plug and socket which must be easily accessible for servicing
and maintenance work after the machine has been installed. An elec-
trical safety test must be carried out after installation and after any
service work.
The machine should be connected with a suitably rated plug and
socket in accordance with IEC 60309-1 or hard wired. For a hard
wired connection an all-pole isolation device must be installed.
For hard-wired machines connection should be made via a suitable
mains switch with all-pole isolation which, when in the off position,
ensures a 3 mm gap between all open contacts. These include cir-
cuit breakers, fuses and relays (IEC/EN 60947).
If the mains supply cannot be permanently disconnected, the isolator
switch (including plug and socket) must be safeguarded against be-
ing switched on either unintentionally or without authorisation.
If it is necessary to install a residual current device (RCD) in ac-
cordance with local regulations, a residual current device type B
(sensitive to universal current) must be used.
An existing type A residual current device (RCD) must be exchanged
for a type B RCD.
If necessary, equipotential bonding with good galvanic contact
must be guaranteed in compliance with all applicable local and na-
tional installation specifications.
Equipotential bonding must have an earth current rating > 10 mA
Accessories for equipotential bonding are not supplied and need to
be ordered separately.
Water connection
For compliance to Regulation 4 of the water regulations guide please
fit the supplied double check valves to the on-site water supplies for
each inlet hose used. The non-return valve prevents water from the
water inlet hose from flowing back into the on-site drinking water
supply.
Non-return valves are supplied.
The flow pressure must amount to a minimum of 100 kPa and must
not exceed 1000 kPa. If the flow pressure is higher than 1000 kPa, a
pressure reducing valve must be used.
The machine must be connected to the water supply using the inlet
hoses provided.
The connection points are subject to water supply pressure.
Turn on the stopcock slowly and check for leaks. Correct the posi-
tion of the seal and screw thread if appropriate.
Summary of Contents for PWM 916 SD
Page 2: ...2 de 4 en 29 fr 53 es 77 ru 102 it 128 ...
Page 22: ...de Aufstellung INSTALLATION 22 Standard Maßangaben in Millimeter Standfuß ...
Page 23: ...de Aufstellung INSTALLATION 23 Sockel Maßangaben in Millimeter ...
Page 46: ...en Installation INSTALLATION 46 Standard Dimensions in mm Machine foot ...
Page 47: ...en Installation INSTALLATION 47 Plinth Dimensions in mm ...
Page 70: ...fr Installation INSTALLATION 70 Par défaut Dimensions en millimètres Pied ...
Page 71: ...fr Installation INSTALLATION 71 Socle Dimensions en millimètres ...
Page 95: ...es Emplazamiento INSTALLATION 95 Estándar Medidas en milímetros Base de apoyo ...
Page 96: ...es Emplazamiento INSTALLATION 96 Zócalo Medidas en milímetros ...
Page 121: ...ru Установка INSTALLATION 121 Стандарт Размеры в мм Ножка ...
Page 122: ...ru Установка INSTALLATION 122 Цоколь Размеры в мм ...
Page 146: ...it Posizionamento INSTALLATION 146 Standard Misure in millimetri Piedino ...
Page 147: ...it Posizionamento INSTALLATION 147 Base Misure in millimetri ...