Caractéristiques techniques 

 

 
 

 

 

 

 

 

 

Lave-linge : 
Type de chauffage : 
 

PW 6207 
Vapeur (D)

 

 

 

Légende :

 

 

Signification des symboles entourés d’un cercle continu : 
raccordement nécessaire

 

 

fr - CA

 

 

 

 

Signification des symboles entourés d’un cercle discontinu : 
raccordement optionnel ou en fonction de la machine

 

 

 

Options/accessoires : 

UO/

UG 

Socle Miele

 

UO 6020 (UO = socle ouvert)

 

 

 

Hauteur

 

9 7/16 po 

240 mm 

 

Largeur 

 

36 ¼ po 

920 mm 

 

 

Profondeur

 

39 ¾ po 

1009 mm 

 

 

UG 6020 ( UG = socle fermé)

 

 

 

 

 

Hauteur

 

9 7/16 po 

240 mm 

 

 

Largeur

 

35 7/16 po 

900 mm 

 

 

Profondeur

 

40 1/8 po 

1019 mm 

BS

 

Socle en béton

 

Hauteur conseillée

 

9 7/16 po 

240 mm 

 

Hauteur minimum

 

3 15/16 po 

100 mm 

 

Largeur de socle min.

 

36 ¼ po 

920 mm 

 

 

Profondeur de socle min.

 

41 5/16 po 

1050 mm 

DAV 

Vanne de 

raccordement 

vapeur

 

La vanne de raccordement vapeur pour la commande de 
l’arrivée de vapeur doit être prévue par l’exploitant. 

Les vannes suivantes de régulation d’écoulement de vapeur 
peuvent également être commandées.

 

 

 

Electrovanne de vapeur (ELD 04)

 

 

29 – 145 psi 
Pouce 
 
 

 

200 – 1000 kPa 
½ po (NPT)

 

230 V

 

60 Hz 

Pression de vapeur régulable

 

Taille de raccordement

 

Tension

 

Fréquence

 

Vanne de vapeur pneumatique (Version CDN)

 

 

 

Pression de vapeur régulable

 

0 – 145 psi 

0 – 1000 kPa 

Taille de raccordement

 

Pouce

 

½ po (NPT)

 

Le raccordement et la commande pneumatique de la vanne 
doivent être prévus par l’exploitant.

 

 

 

 

Pompe de 

distribution 

Pompes de distribution externes (avec 2 ou 4 pompe) : 

 

 

 

Tension (alimentation externe requise) 

 

120V  

 

 

Fusible 

 

15A

 

 

 

Fourni avec câble et connecteur d'alimentation 

 

NEMA 5-15

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Plan d’installation : PW 6207 D (vapeur) 

Date: 03/2015 

 

Page: 15 

 

Summary of Contents for PW 6207

Page 1: ...12 15 M Nr 10 010 800 00 Installation plan Washer PW 6207 D Steam PW 6207 D Vapeur en fr CA Plan d installation Lave linge ...

Page 2: ...M Nr 10 010 800 00 2 ...

Page 3: ...40 3 8 17 3 8 1 44 1 2 40 1 8 3 3 8 57 1 8 55 1 8 20 3 8 19 1 2 36 3 8 36 1 4 2 2 55 1 8 23 5 8 14 5 8 44 1 2 57 1 8 40 1 8 36 3 8 36 1 4 PW 6207 D measurements in inches mesures en pouces 3 ...

Page 4: ...63 7 7 8 6 3 4 63 6 3 4 6 1 4 3 3 8 4 7 8 63 63 6 1 4 4 7 8 6 3 4 7 7 8 23 5 8 6 3 4 PW 6207 D measurements in inches mesures en pouces 4 ...

Page 5: ...55 1 8 55 1 8 4 57 1 8 57 1 8 41 3 8 36 1 4 36 1 4 29 7 8 29 7 8 15 15 40 1 8 34 5 8 34 5 8 3 3 8 3 3 8 19 19 4 4 5 8 5 8 PW 6207 D measurements in inches mesures en pouces 5 ...

Page 6: ...55 1 8 9 1 2 57 1 8 39 3 4 40 1 8 36 1 4 35 3 8 18 1 4 37 1 4 16 1 2 33 2 1 2 1 2 PW 6207 D measurements in inches mesures en pouces 6 ...

Page 7: ...PW 6207 D measurements in millimeters mesures en millimètres 7 ...

Page 8: ...PW 6207 D measurements in millimeters mesures en millimètres 8 ...

Page 9: ...PW 6207 D measurements in millimeters mesures en millimètres 9 ...

Page 10: ...PW 6207 D measurements in millimeters mesures en millimètres 10 ...

Page 11: ...connection valve The steam connection valve to regulate the steam supply must be provided on site The following valves can be ordered separately as electric steam valves or as pneumatic steam valves Electric steam valve ELD 04 29 145 psi Regulatable steam pressure 200 1000 kPa Connection gauge Inch NPT Voltage 230V Frequency 60 Hz Pneumatic steam valve CDN version Regulatable steam pressure 0 145 ...

Page 12: ...ui potential bonding Option Sleeve with external thread 3 8 x 1 3 8 10 35 mm for washer and nut M 10 Fitting such as washers and nuts are only supplied with the OS machine version If necessary equipotential bonding with good galvanic contact must be provided in accordance with all appropriate national and local regulations Steam connection Indirect steam Steam pressure 87 145 psi 600 1 000 kPa Boi...

Page 13: ...h Approx 108 l h If hot water is not available connect hot water hose to cold water valve Cold water hard water Min water pressure flow pressure 14 5 psi 100 kPa Max water pressure flow pressure 145 psi 1000 kPa Max throughput 8 5 gal min 32 l min Option Optional retrofit kit 2 inlet hoses with threaded union female On site connection thread Inch garden hose thread male Length of inlet hose 59 1 1...

Page 14: ...8 12 x 60 mm Both the machine and the base must be installed according to the installation instructions provided Machine data Machine width 36 3 8 924 mm Machine depth 44 1130 mm Machine height 55 1 8 1400 mm Casing width 36 920 mm Casing depth 40 3 16 1020 mm Min width of delivery access to installation site 36 5 8 930 mm Recommended rear wall gap measured to front of machine 57 1 16 1450 mm Mini...

Page 15: ...in 41 5 16 po 1050 mm DAV Vanne de raccordement vapeur La vanne de raccordement vapeur pour la commande de l arrivée de vapeur doit être prévue par l exploitant Les vannes suivantes de régulation d écoulement de vapeur peuvent également être commandées Electrovanne de vapeur ELD 04 29 145 psi Pouce 200 1000 kPa po NPT 230 V 60 Hz Pression de vapeur régulable Taille de raccordement Tension Fréquenc...

Page 16: ...ns nationales et locales Liaison équipotentielle en option Tubulure à filetage extérieur 3 8 x 1 3 8 po 10 35 mm avec rondelles et écrou M 10 Les accessoires tels que les rondelles et les écrous ne sont fourni qu avec la version OS En fonction des règlements locaux il peut être nécessaire d établir une liaison équipotentielle avec une bonne liaison des contacts Raccordement à la vapeur Pression de...

Page 17: ...re env 28 5 gal h env 108 l h S il n y a pas d alimentation en eau chaude disponible raccorder à l eau froide Eau froide eau dure en option Surpression eau pression d écoulement min 14 5 psi 100 kPa Surpression eau pression d écoulement max 145 psi 1000 kPa Débit volumétrique max 8 5 gal min 32 l min En option kit de rattrapage avec 2 flexibles de raccordement avec raccord Raccord fileté à prévoir...

Page 18: ...eur pour la fixation po 12 mm La fixation doit être effectuée conformément aux règlements locaux et à la situation sur place L appareil est livré sans pieds de sorte que le filetage intérieur peut être utilisé pour une fixation avec boulons Caractéristiques Largeur appareil 36 3 8 po 924 mm Profondeur appareil 44 po 1130 mm Hauteur appareil 55 1 8 po 1400 mm Largeur carrosserie 36 po 920 mm Profon...

Reviews: