background image

 

 

Cold water

 

(soft water) 

Min. water pressure/flow pressure 

14.5 psi 

100 kPa 

Max. water pressure/flow pressure 

145 psi 

1000 kPa 

Max. throughput 

6.9 gal/min 

26 l/min 

 

 

Max. throughput (if hot or raw water supply is not available) 

11.1 gal/min 

42 l/min 

 

 

2 inlet hoses with ¾" threaded union (female) 

 

 

 

 

On-site connection thread  

Inch 

¾" garden hose 

thread, male 

 

 

 

Length of inlet hose 

59 1/16“ 

1500 mm

 

 

 

Hourly water demand (average for 60°C cotton program) 

determined at cold, hot and raw water connection  

 Approx. 33 

gal/h  

Approx. 124 l/h 

 

 

Add the hot water requirement to the cold water requirement, 

if there is no hot water supply available. 

 

 

 

 

If connected to hard water supply, subtract cold water (soft) 

volume. 

 

 

 

Hot water  

(soft water) 

Max. water temperature 

158°F 

70°C 

Min. water pressure/flow pressure 

14.5 psi 

100 kPa 

Max. water pressure/flow pressure 

145 psi 

1000 kPa 

 

 

Max. throughput  

4.2 gal/min 

16 l/min 

 

 

1 inlet hose with ¾" threaded union supplied. 

 

 

 

 

On-site connection thread 

Inch 

¾" garden hose 

thread, male 

 

 

Length of inlet hose 

59 1/16“ 

1500 mm

 

 

 

Hourly water demand (average for 60°C cotton program) 

determined at cold, hot and raw water connection  

Approx. 28.5 

gal/h  

Approx. 108 l/h 

 

 

If hot water is not available, connect hot water hose to cold 

water valve! 

 

 

 

Cold water

 

(hard water)  

 

Min. water pressure/flow pressure 

14.5 psi 

100 kPa 

Max. water pressure/flow pressure 

145 psi 

1000 kPa 

Max. throughput 

8.5 gal/min 

32 l/min 

 

(Option) 

Optional retrofit kit: 2 inlet hoses with ¾" threaded union 

(female) 

 

 

 

On-site connection thread  

 

Inch 

¾" garden hose 

thread, male 

 

 

Length of inlet hose 

59 1/16“ 

1500 mm

 

 

 

Hourly water demand (average for 60° cotton program) 

determined at cold, hot and hard water connection 

Approx.19.5 

gal/h  

Approx. 74 l/h 

 

Cold water

 

Liquid  

dispensing 

 

 

Min. water pressure/flow pressure 

14.5 psi 

100 kPa 

Max. water pressure/flow pressure 

145 psi 

1000 kPa 

Max. throughput 

1.5 gal/min 

5.5 l/min 

 

(Option) 

1 inlet hose with ¾" threaded union included  

(optional). 

 

 

 

 

On-site connection thread  

Inch 

¾" garden hose 

thread, male 

 

 

 

Length of inlet hose 

59 1/16“ 

1500 mm

 

 

Waste water

 

Drain valve

 

 

Max. waste water temperature 

203°F 

95°C 

Waste water connection on machine (ext. diameter) 

2 15/16“ 

75 mm [DN 70] 

Drain connection on site (int. diameter) 

2 15/16“ 

75 mm [DN 70] 

Max. transient throughput 

52.9 gal/min 

200 l/min 

 

 

Vented drainage required. If ventilation is insufficient, fit Miele 

kit, Mat. No. 05238090.

 

Drain manifolds serving several machines must be of 

sufficient cross-section. 

 

 

 

 

Technical datasheet: PW 6207 D (steam) 
Date: 03/2015 

 

Page: 13 

 

Summary of Contents for PW 6207

Page 1: ...12 15 M Nr 10 010 800 00 Installation plan Washer PW 6207 D Steam PW 6207 D Vapeur en fr CA Plan d installation Lave linge ...

Page 2: ...M Nr 10 010 800 00 2 ...

Page 3: ...40 3 8 17 3 8 1 44 1 2 40 1 8 3 3 8 57 1 8 55 1 8 20 3 8 19 1 2 36 3 8 36 1 4 2 2 55 1 8 23 5 8 14 5 8 44 1 2 57 1 8 40 1 8 36 3 8 36 1 4 PW 6207 D measurements in inches mesures en pouces 3 ...

Page 4: ...63 7 7 8 6 3 4 63 6 3 4 6 1 4 3 3 8 4 7 8 63 63 6 1 4 4 7 8 6 3 4 7 7 8 23 5 8 6 3 4 PW 6207 D measurements in inches mesures en pouces 4 ...

Page 5: ...55 1 8 55 1 8 4 57 1 8 57 1 8 41 3 8 36 1 4 36 1 4 29 7 8 29 7 8 15 15 40 1 8 34 5 8 34 5 8 3 3 8 3 3 8 19 19 4 4 5 8 5 8 PW 6207 D measurements in inches mesures en pouces 5 ...

Page 6: ...55 1 8 9 1 2 57 1 8 39 3 4 40 1 8 36 1 4 35 3 8 18 1 4 37 1 4 16 1 2 33 2 1 2 1 2 PW 6207 D measurements in inches mesures en pouces 6 ...

Page 7: ...PW 6207 D measurements in millimeters mesures en millimètres 7 ...

Page 8: ...PW 6207 D measurements in millimeters mesures en millimètres 8 ...

Page 9: ...PW 6207 D measurements in millimeters mesures en millimètres 9 ...

Page 10: ...PW 6207 D measurements in millimeters mesures en millimètres 10 ...

Page 11: ...connection valve The steam connection valve to regulate the steam supply must be provided on site The following valves can be ordered separately as electric steam valves or as pneumatic steam valves Electric steam valve ELD 04 29 145 psi Regulatable steam pressure 200 1000 kPa Connection gauge Inch NPT Voltage 230V Frequency 60 Hz Pneumatic steam valve CDN version Regulatable steam pressure 0 145 ...

Page 12: ...ui potential bonding Option Sleeve with external thread 3 8 x 1 3 8 10 35 mm for washer and nut M 10 Fitting such as washers and nuts are only supplied with the OS machine version If necessary equipotential bonding with good galvanic contact must be provided in accordance with all appropriate national and local regulations Steam connection Indirect steam Steam pressure 87 145 psi 600 1 000 kPa Boi...

Page 13: ...h Approx 108 l h If hot water is not available connect hot water hose to cold water valve Cold water hard water Min water pressure flow pressure 14 5 psi 100 kPa Max water pressure flow pressure 145 psi 1000 kPa Max throughput 8 5 gal min 32 l min Option Optional retrofit kit 2 inlet hoses with threaded union female On site connection thread Inch garden hose thread male Length of inlet hose 59 1 1...

Page 14: ...8 12 x 60 mm Both the machine and the base must be installed according to the installation instructions provided Machine data Machine width 36 3 8 924 mm Machine depth 44 1130 mm Machine height 55 1 8 1400 mm Casing width 36 920 mm Casing depth 40 3 16 1020 mm Min width of delivery access to installation site 36 5 8 930 mm Recommended rear wall gap measured to front of machine 57 1 16 1450 mm Mini...

Page 15: ...in 41 5 16 po 1050 mm DAV Vanne de raccordement vapeur La vanne de raccordement vapeur pour la commande de l arrivée de vapeur doit être prévue par l exploitant Les vannes suivantes de régulation d écoulement de vapeur peuvent également être commandées Electrovanne de vapeur ELD 04 29 145 psi Pouce 200 1000 kPa po NPT 230 V 60 Hz Pression de vapeur régulable Taille de raccordement Tension Fréquenc...

Page 16: ...ns nationales et locales Liaison équipotentielle en option Tubulure à filetage extérieur 3 8 x 1 3 8 po 10 35 mm avec rondelles et écrou M 10 Les accessoires tels que les rondelles et les écrous ne sont fourni qu avec la version OS En fonction des règlements locaux il peut être nécessaire d établir une liaison équipotentielle avec une bonne liaison des contacts Raccordement à la vapeur Pression de...

Page 17: ...re env 28 5 gal h env 108 l h S il n y a pas d alimentation en eau chaude disponible raccorder à l eau froide Eau froide eau dure en option Surpression eau pression d écoulement min 14 5 psi 100 kPa Surpression eau pression d écoulement max 145 psi 1000 kPa Débit volumétrique max 8 5 gal min 32 l min En option kit de rattrapage avec 2 flexibles de raccordement avec raccord Raccord fileté à prévoir...

Page 18: ...eur pour la fixation po 12 mm La fixation doit être effectuée conformément aux règlements locaux et à la situation sur place L appareil est livré sans pieds de sorte que le filetage intérieur peut être utilisé pour une fixation avec boulons Caractéristiques Largeur appareil 36 3 8 po 924 mm Profondeur appareil 44 po 1130 mm Hauteur appareil 55 1 8 po 1400 mm Largeur carrosserie 36 po 920 mm Profon...