Cold water
(soft water)
Min. water pressure/flow pressure
14.5 psi
100 kPa
Max. water pressure/flow pressure
145 psi
1000 kPa
Max. throughput
6.9 gal/min
26 l/min
Max. throughput (if hot or raw water supply is not available)
11.1 gal/min
42 l/min
2 inlet hoses with ¾" threaded union (female)
On-site connection thread
Inch
¾" garden hose
thread, male
Length of inlet hose
59 1/16“
1500 mm
Hourly water demand (average for 60°C cotton program)
determined at cold, hot and raw water connection
Approx. 33
gal/h
Approx. 124 l/h
Add the hot water requirement to the cold water requirement,
if there is no hot water supply available.
If connected to hard water supply, subtract cold water (soft)
volume.
Hot water
(soft water)
Max. water temperature
158°F
70°C
Min. water pressure/flow pressure
14.5 psi
100 kPa
Max. water pressure/flow pressure
145 psi
1000 kPa
Max. throughput
4.2 gal/min
16 l/min
1 inlet hose with ¾" threaded union supplied.
On-site connection thread
Inch
¾" garden hose
thread, male
Length of inlet hose
59 1/16“
1500 mm
Hourly water demand (average for 60°C cotton program)
determined at cold, hot and raw water connection
Approx. 28.5
gal/h
Approx. 108 l/h
If hot water is not available, connect hot water hose to cold
water valve!
Cold water
(hard water)
Min. water pressure/flow pressure
14.5 psi
100 kPa
Max. water pressure/flow pressure
145 psi
1000 kPa
Max. throughput
8.5 gal/min
32 l/min
(Option)
Optional retrofit kit: 2 inlet hoses with ¾" threaded union
(female)
On-site connection thread
Inch
¾" garden hose
thread, male
Length of inlet hose
59 1/16“
1500 mm
Hourly water demand (average for 60° cotton program)
determined at cold, hot and hard water connection
Approx.19.5
gal/h
Approx. 74 l/h
Cold water
Liquid
dispensing
Min. water pressure/flow pressure
14.5 psi
100 kPa
Max. water pressure/flow pressure
145 psi
1000 kPa
Max. throughput
1.5 gal/min
5.5 l/min
(Option)
1 inlet hose with ¾" threaded union included
(optional).
On-site connection thread
Inch
¾" garden hose
thread, male
Length of inlet hose
59 1/16“
1500 mm
Waste water
Drain valve
Max. waste water temperature
203°F
95°C
Waste water connection on machine (ext. diameter)
2 15/16“
75 mm [DN 70]
Drain connection on site (int. diameter)
2 15/16“
75 mm [DN 70]
Max. transient throughput
52.9 gal/min
200 l/min
Vented drainage required. If ventilation is insufficient, fit Miele
kit, Mat. No. 05238090.
Drain manifolds serving several machines must be of
sufficient cross-section.
Technical datasheet: PW 6207 D (steam)
Date: 03/2015
Page: 13
Summary of Contents for PW 6207
Page 2: ...M Nr 10 010 800 00 2 ...
Page 7: ...PW 6207 D measurements in millimeters mesures en millimètres 7 ...
Page 8: ...PW 6207 D measurements in millimeters mesures en millimètres 8 ...
Page 9: ...PW 6207 D measurements in millimeters mesures en millimètres 9 ...
Page 10: ...PW 6207 D measurements in millimeters mesures en millimètres 10 ...