Page 5: ......

Page 6: ......

Page 7: ...cross section M 32 mm 5 6 0 2 Standard voltage as supplied V 3 AC 220 240 Frequency Hz 50 60 Rated load kW 21 Fuse rating A 3 63 Supply lead min cross section M 40 mm 4 16 3 Standard voltage as supplied V 3 AC 440 Frequency Hz 60 Rated load kW 21 Fuse rating A 3 35 Supply lead min cross section M 32 mm 4 6 0 Plug and socket connection recommended to facilitate electrical safety tests Socket must b...

Page 8: ...ater requirements average for 60 C programme Standard connection with hot water connection l h not yet available If connected to raw water supply subtract cold water soft volume If no raw water supply connect hose to cold water Max temperature C 95 Machine drain connection da s l DN 70 mm 75 1 9 115 On site drain connection di s l DN 70 sleeve mm 75 1 9 50 Drainage via dump valve Max transient thr...

Page 9: ...ked down dimensions W H mm 1100 x 1500 Recommended gap to opposite wall mm 1450 Net weight kg 499 Dynamic floor load max N 6076 Static floor load max N 5543 Drum frequency max Hz 18 3 Average heat dissipation dependent on ambient room temperature and programme selected W not yet available Installation should only be carried out by authorised fitters in accordance with valid regulations Observe ins...