background image

en 

– AU, NZ 

PW 6055/6065 

 = standard, 

 = optional, + = only on request, - not available 

14 

 

10 291 510 / 01 

Technical data 

 

PW 6055 AV 

PW 6055 LP 

PW 6065 AV 

PW 6065 LP 

P e a k   l o a d   /   E n e r g y  m a n a g e m e n t   ( S L A )

 

 

 

 

 

 

Machine connection (separate kit required)

 

 

 

 

 

 

Control signal voltage 

 

AC 230 V 

AC 230 V 

AC 230 V 

AC 230 V 

 

 

 

 

 

 

P a ym e n t   s ys t e m   c o n n e c t i o n   ( K G A )

 

 

 

 

 

 

Connection of payment systems 

 

 

 

 

 

 

 

 

 

 

 

C o m m u n i c a t i o n   m o d u l e   ( X K M )  

 

 

 

 

 

RS 232 serial interface (XKM module retrofitting kit) 

 

 

 

 

 

 

 

 

 

 

 

L i q u i d   d i s p e n s i n g   ( D O S )

 

 

 

 

 

 

Connection for liquid detergents (conversion kit required)

 

 

 

 

-

 

-

 

Connection for liquid detergents 

 

 

 

No. of dispenser pumps, max. 

No. 

 

 

 

 

 

 

I n s t a l l a t i o n   o n   m a c h i n e   f e e t   ( F )  

 

 

 

 

 

No. of machine feet 

No. 

Machine foot, height-adjustable with thread 

mm 

±4 

±4 

±4 

±4 

Machine foot diameter 

mm 

40 

40 

40 

40 

 

 

 

 

 

 

A n c h o r i n g   ( B )

 

 

 

 

 

 

Standard anchoring

 

 

 

 

 

 

Floor anchor kit (for 2 machine feet)

 

 

 

 

 

 

Wood screws according to DIN 571 

mm 

6 x 50 

6 x 50 

6 x 50 

6 x 50 

Rawl plugs (diameter x length) 

mm 

8 x 40 

8 x 40 

8 x 40 

8 x 40 

 

 

 

 

 

 

Anchoring of Miele plinths 

 

 

 

 

 

Accessory: Miele plinth (fasteners included) 

 

 

 

 

 

Required anchor points 

No. 

Wood screws according to DIN 571 

mm 

8 x 65 

8 x 65 

8 x 65 

8 x 65 

Rawl plugs (diameter x length) 

mm 

12 x 60 

12 x 60 

12 x 60 

12 x 60 

 

 

 

 

 

 

Plinth floor anchoring (to be provided on site) 

 

 

 

 

 

Machine installation on permanent plinth (concrete or masonry) 

 

 

 

 

 

Plinth installation footprint (W/D) 

mm 

600/650 

600/650 

600/650 

600/650 

Wood screws according to DIN 571 

mm 

6 x 50 

6 x 50 

6 x 50 

6 x 50 

Rawl plugs (diameter x length) 

mm 

8 x 40 

8 x 40 

8 x 40 

8 x 40 

 

 

 

 

 

 

M a c h i n e   d a t a

 

 

 

 

 

 

Overall machine dimensions (H/W/D)

 

mm

 

850/600/722

 

850/605/715

 

850/600/722

 

850/605/715

 

Casing dimensions (H/W/D) 

mm 

850/595/697 

850/595/697 

850/595/697 

850/595/697 

Site-access dimensions (H/W)

 

 

 

 

 

 

Min. site-access (excl. packaging) 

mm 

900/600 

900/600 

900/600 

900/600 

Installation dimensions

 

 

 

 

 

 

Min. side gap

 

mm

 

20

 

20

 

20

 

20

 

Recommended side gap - washer-dryer stack 

mm 

>300 

>300 

>300 

>300 

Min. distance to opposite wall from front of machine 

mm 

900 

900 

900 

900 

Recommended distance to opposite wall from front of machine 

mm 

1100 

1100 

1100 

1100 

Weights and floor loads

 

 

 

 

 

 

Machine weight (net weight) 

kg 

106 

106 

109 

109 

Max. floor load in operation

 

N

 

2820

 

2820

 

2820

 

2820

 

Max. floor load, static 

1380 

1380 

1455 

1455 

Max. floor load, dynamic 

1365 

1365 

1365 

1365 

Max. drum rotation frequency 

Hz 

22 

22 

22 

22 

Emissions

 

 

 

 

 

 

Sound pressure level in accordance with EN ISO 11204/11203 

dB(A) 

<70 

<70 

<70 

<70 

Heat dissipation rate to installation site 

250 

250 

250 

250 

 

 

 

 

 

 

 

Summary of Contents for PW 6055 AV/LP

Page 1: ...65 AV LP To avoid the risk of accidents or damage to the machine it is essential to read operating and installation instructions before installation and commissioning This will prevent both personal injury and damage to the machine en AU NZ 10 291 510 01 ...

Page 2: ...in pump B Machine anchors PA Equipotential bonding BW Grey water connection SLA Peak load connection DOS Dispenser connection UG Box plinth EL Electrical connection UO Open plinth F Machine feet adjustable WTV Washer dryer stacking kit KG Payment system WW Hot water connection KGA Payment system connection XKM Communication module All rights reserved 06 15 27 ...

Page 3: ...PW 6055 6065 en AU NZ 10 291 510 01 3 Machine dimensions PW 6055 ...

Page 4: ...en AU NZ PW 6055 6065 4 10 291 510 01 Installation PW 6055 ...

Page 5: ...PW 6055 6065 en AU NZ 10 291 510 01 5 Washer dryer stack PW 6055 ...

Page 6: ...en AU NZ PW 6055 6065 6 10 291 510 01 Machine dimensions PW 6065 ...

Page 7: ...PW 6055 6065 en AU NZ 10 291 510 01 7 Installation PW 6065 ...

Page 8: ...en AU NZ PW 6055 6065 8 10 291 510 01 Washer dryer stack PW 6065 ...

Page 9: ...PW 6055 6065 en AU NZ 10 291 510 01 9 Installation ...

Page 10: ...en AU NZ PW 6055 6065 10 10 291 510 01 Installation ...

Page 11: ... Fuse rating B trip rating according to EN 60898 A 3 x 16 3 x 16 Supply lead min cross section mm 4 x 1 5 4 x 1 5 Supply lead without plug for hard wired connection Length of supply lead mm 1800 1800 Non standard voltage OS 400 Offshore 3 AC 400 V Frequency Hz 50 Total rated load kW 4 2 Fuse rating B trip rating according to EN 60898 A 3 x 16 Supply lead min cross section mm 4 x 1 5 Supply lead wi...

Page 12: ...000 2000 2000 2000 Standard voltage B only 3 AC 230 V 3 AC 230 V Frequency Hz 50 50 Total rated load kW 5 5 5 5 Fuse rating B trip rating according to EN 60898 A 3 x 20 3 x 20 Supply lead min cross section mm 4 x 2 5 4 x 2 5 Supply lead without plug for hard wired connection Length of supply lead mm 2000 2000 Alternative voltage convertible 2N AC 400 V 2N AC 400 V Total rated load kW 5 5 5 5 Fuse ...

Page 13: ...temperature C 70 70 70 70 Permissible water flow pressure kPa 100 1000 100 1000 100 1000 100 1000 Min flow rate l min 11 11 11 11 Average water consumption 60 C standard programme l h 13 13 13 13 Connection to be provided on site external thread according to AS 3688 Inch Connection hose with threaded union Connection hose length mm 1550 1550 1550 1550 Alternative water supply BW Kit with additiona...

Page 14: ...gs diameter x length mm 12 x 60 12 x 60 12 x 60 12 x 60 Plinth floor anchoring to be provided on site Machine installation on permanent plinth concrete or masonry Plinth installation footprint W D mm 600 650 600 650 600 650 600 650 Wood screws according to DIN 571 mm 6 x 50 6 x 50 6 x 50 6 x 50 Rawl plugs diameter x length mm 8 x 40 8 x 40 8 x 40 8 x 40 Machine data Overall machine dimensions H W ...

Page 15: ...er stacking kit Lotus white kit WTV 5061 Washer dryer stacking kit Payment systems KG Single unit C 4060 Payment system for tokens programme operation only Single unit C 4065 Payment system for euro coins time and programme operation Single unit C 4070 Payment system for tokens and euro coins time and programme operation Multi machine unit C 5200 BT Base unit for GeldKarte transactions for max 8 m...

Page 16: ...connection The machine should be connected to a mains water supply in accordance with current local and national regulations on water safety IMPORTANT Australia and New Zealand This appliance must be installed according to AS NZS 3500 1 This appliance has been supplied with a separate backflow prevention device Add drawing and instructions as per below for installing the non return valve Disconnec...

Page 17: ...em optional accessory The necessary programming should only be performed by a qualified agent or by Miele Alternatively a wireless multi machine system for a maximum of 8 units can be connected to a Geldkarte payment system and further controls used to monitor machines Serial interface The serial interface is provided by an additional XKM RS323 module The led through data interface from the XKM RS...