Problem
Possible cause
Remedy
There is a build-up
of condensed water
in the drum.
There is more than one
tumble dryer vented
together.
– The dryer must only be
connected to a joint ducting
system if a non-return flap is
in place.
– Check the non-return flap
regularly for damage, and
exchange it if necessary.
The interior drum
lighting does not
come on.
The lighting switches
off automatically (to
save energy).
– It will switch on again after
the door has been closed
and then opened.
– If the lamp needs to be
replaced, follow the
instructions in "Changing the
lamp" at the end of this
section.
Power cuts.
– After the power supply has been restored, switch the
dryer on using the
s
button.
– Confirm with
OK
.